5.2   Open-window function

living connect®

 features an Open-window function, which 

closes the valve if the room temperature is falling 

dramatically, thus reducing the heat loss.

The heat is turned off in the entire room for up to 30 

minutes, before 

living connect®

 returns to its original 

settings.

When Open-window has been activated, the function is 

quarantined for 45 minutes.

Note! Be aware that the Open-window function will be 

affected, if curtains or furniture is covering living connect®, 

thus preventing it from detecting the decreasing temperature.

5.3   Automatic valve exercising

To keep the radiator valve functional and at its best, 

living connect

®

 automatically exercises the 

valve every Thursday at approx. 11:00 hrs by opening it fully and then return to normal setting.

6. Safety precautions

The thermostat is not intended for children and must not be used as a toy.

Do not leave packaging materials where children may be tempted to play with them, as this is 

extremely dangerous.

Do not attempt to dismantle the thermostat as it contains no user-serviceable parts. If error code 

E1, E2 etc. is shown in the display or other defects appear, please return the thermostat to the 

distributor.

7. Disposal

The thermostat must be disposed of as electronic waste.

Summary of Contents for living connect

Page 1: ...Danfoss Heating Solutions VIIDH102 11 2013 1 Installation and User Guide living connect Electronic Radiator Thermostat...

Page 2: ...8 1 8 Automatic adjustments 8 1 9 Removing living connect 9 1 10 Resetting living connect to default settings 9 1 11 Removing an adapter from living connect 10 2 Technical specifications 11 Pay a vis...

Page 3: ...g living connect to a Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC 12 4 2 Connecting living connect to Danfoss Link CC 12 4 3 Testing the connection 14 5 Additional settings 5 1 Adjust...

Page 4: ...e mounted adapter for Danfoss RA valves two alkaline AA batteries a 2 mm Allen key and a Quick Guide in languages English German Danish Dutch French Polish Swedish and Finnish living eco Quick Start G...

Page 5: ...are available as accessories Adapter type Code no Adapter Valve For Danfoss RA valves 014G0251 For M30 x 1 5 K valves 014G0252 For Danfoss RAV valves 014G0250 34 For Danfoss RAVL valves 26 For Danfoss...

Page 6: ...the 2 mm Allen key Adapter for M30 x 1 5 K valves 1 2 Place the K adapter on the valve as shown Hand tighten the K adapter max 5 Nm Adapter for RAV valves accessory 1 2 Click the inner adapter on the...

Page 7: ...ol is displayed approx one month before the batteries run out After approx two weeks the symbol will flash 14 times from 19 00 to 21 00 hrs Before the batteries run out living connect will leave the v...

Page 8: ...f operation living connect will shut off the radiator heat and then open again to detect the exact opening point of the valve This will allow living connect to control the heat as efficiently as possi...

Page 9: ...dicate that Installation Mode is activated 3 4 Remove the battery cover and the batteries Insert the Allen key or similar into the hole to lock the adapter ring Turn counterclockwise to unscrew living...

Page 10: ...t a small hex key or similar into the locking hole to lock the adapter ring 3 4 With the hex key locking the adapter ring turn the adapter in the shown direction Put back the battery cover Mount livin...

Page 11: ...ttery level is critical the whole display will flash Ambient temperature range 0 to 40 C Transportation temperature range 20 to 65 C Maximum water temperature 90 C Temperature setting range 4 to 28 C...

Page 12: ...Danfoss Link system 4 1 Configuring rooms in Danfoss Link CC Make sure that the room in which living connect has been installed has been configured in Danfoss Link CC see installation guide for Danfo...

Page 13: ...r No 6 Heating System Mode Decide what the heating system prioritizes Heating with low return temperature recommended for district heating Fast heating with warm radiators recommended for boilers Mode...

Page 14: ...m and antenna symbols will both be flashing Refer to Technical questions at www living danfoss eu 5 Additional settings 5 1 Adjusting to radiator room conditions Press for at least 3 seconds until M i...

Page 15: ...s preventing it from detecting the decreasing temperature 5 3 Automatic valve exercising To keep the radiator valve functional and at its best living connect automatically exercises the valve every Th...

Page 16: ...n and User Guide living connect Danfoss A S Haarupvaenget 11 DK 8600 Silkeborg Denmark Phone 45 7488 8000 Fax 45 7488 8100 www danfoss com www living danfoss eu Installer VIIDH102 Produced by Danfoss...

Reviews: