Operating guide | iSave 50 - 70
7
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
•
It is always the system builders’
responsibility that the system design does
not cause any form of hazard and are
adapted to local regulations.
•
Proper installation and care of shutdown
devices and over-pressure protection
equipment is essential.
3.4 Preferred system design
Danfoss recommends building systems with
a high degree of safety. Our preferred system
design can be found in the data heet in appendix
10.1.
4.
Arrival inspection,
handling and storage
4.1 Arrival inspection
The iSave is packed in a wood container.
The iSave ports connector are protected by
plastic caps that protect the iSave against dust
and particles. Do not remove the caps before the
system have been flushed and the iSave can be
installed.
Remove all packing materials immediately after
delivery. Immediately check the shipment for
damage on arrival and make sure that the name
plate/type designation is in accordance with the
packing slip and your order.
In case of damage and/or missing parts, a report
should be drawn up and presented o the carrier
at once.
The identification label on the iSave states the
specific type, the serial number and the code
number of the iSave; see fig. below.
The last three digits of the Serial No. indicate the
week and year of production.
PUMP
Type iSave 50 ERD
Code no. 180FXXXX
Serial no. XXXXXX02-XXX
MADE IN DENMARK
Danfoss A/S, 6430 Nordborg, Denmark
4.2 Return to the supplier
Flush the iSave with clean water. Drain the iSave
and plug the port connections with a cap/cover.
Pack the iSave into a suitable container and make
sure that it is suitably fastened to the container.
Please coordinate the shipment with your local
authorized distributor or contact anfoss direct to
obtain a return shipping address.
4.3 Transport and Handling
•
•
Personnel involved in lifting and
transportation of the equipment must be
trained in proper handling and safety
procedures.
•
Observe the local regulations regarding
lifting.
•
Use suitable, permitted lifting equipment.
•
The iSave (set) could slip the lifting
arrangement.
•
Be aware of individuals located in the
operation area while lifting the
component.
The weight of the iSave including electric
motor can be found in the datasheet.
All parts weighing more than 20 kg (44 lb)
must be lifted using lifting slings and suitable
lifting devices, e.g. an overhead crane
or fork lift.
Do not use connections/nozzles for
lifting. Do not use only one sling! Make
sure that the load is balanced before
attempting the lift.
When lifting the ERD without motor use
the lifting eye
s.
When you have finished using the lifting eyes,
remove them to prevent corrosion.
Summary of Contents for iSave 50
Page 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Page 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Page 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Page 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Page 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Page 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Page 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Page 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Page 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Page 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Page 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...