![Danfoss iSave 50 Operating Manual Download Page 29](http://html1.mh-extra.com/html/danfoss/isave-50/isave-50_operating-manual_3487204029.webp)
Data sheet | iSave 50 and iSave 70
29
180R9357 | AQ265943679828en-00100
2
IOM iSave 50 - 70 | 0
3
.202
3
4.3 iSave with NEMA motor
iSave size
iSave 50
iSave 70
Code number (vertical)
180U0062
180U0064
Code number (horizontal)
180U0003
180U0005
Pressure, Speed, Flow, Temperatue and Torque are identical with
180F7020
180F7021
Efficiency
Efficiency at max. speed at 60 barg (871 psig)
7)
%
93.7
92.4
Technical specifications
Media temperature
5
)
°C
2-35
2-35
°F
36-95
36-95
Filtration requirements (nominal)
6)
3 micron melt-blown
Weight (dry) vertical/horizontal
kg
484/506
484/506
lb
1067/1116
1067/1116
Weight (operation with water) vertical/
horizontal
kg
513/535
513/535
lb
1131/1179
1131/1179
Noise
Sound pressure level L
PA
1 m
2)
dB(A)
83
86
Footprint
Footprint (vertical position)
3)
m²
0.44
0.44
foot²
4.71
4.71
Footprint (horizontal position)
3)
m²
0.76
0.76
foot²
8.14
8.14
Torque data
Max. allowable working torque
Nm
170
177
lbf-ft
125
130.5
Max. starting torque (stick/slip)
Nm
180
180
lbf-ft
132
132
Motor data
Nominal speed
rpm
1180
1180
Rated current at 400V
A
36.2
36.2
Motor size
kW
22.5
22.5
HP
30.0
30.0
Frame size
NEMA
324/6T
324/6T
Poles
6
6
Rated motor torque at nominal speed
Nm
179
179
lbf-ft
132
132
Rated motor ambient temperature
4)
°C
40
40
°F
104
104
Motor insulation
Class
B
B
Motor degrees of protection
IP
55
55
2)
A-weighted sound pressure level at 1 m from the ERD
unit surfaces (reference box) acc. to EN ISO 20361
section 6.2. The noise measurement are performed
acc. to EN ISO 3744:2010 on an ERD with motor
(motor pump unit) from min. to max. pressure and
speed.
3
Area covered with recommended IE3 motor
configurations (excl. of space to service the ERD)
)
4)
For higher temperature, contact Danfoss.
5)
Dependent on NaCI concentation.
6)
Please see section 7.4 Filtration
7)
Typical efficiency for pressure exchanger,
. .
booster pump, electrical motor and VFD at 3
barg differential pressure after a system has . . .
been commissioned and run in.
Summary of Contents for iSave 50
Page 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Page 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Page 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Page 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Page 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Page 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Page 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Page 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Page 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Page 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Page 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...