Max. allowable working pressure of continous
operation. For lower and higher pressure, please
contact Danfoss.
2)
Typical pressure level at start-up and permeate
flush.
3)
Intermittent pressure is acceptable for less than 10
minutes within a period of 6 hours.
4)
Typical average flow at 60 barg and 3 barg
differential pressure
5)
Dependent on NaCI concentation.
6)
Please see section 7.4 filtration.
7)
Continuous operation: iSave can operate
continuously with up to 10% over flush with the
limitation that the flow rate at LP inlet shall not
exceed 70 m
3
/h.
8)
A-weighted sound pressure level at 1 m from the
pump unit surfaces (reference box) acc. to EN ISO
20361 section 6.2. The noise measurements are
performed acc. to EN ISO 3744:2010 on a motor-
pump-unit at max. pressure and rpm.
9)
Balanced flow: The mixing rate is defined at
balanced flow when HP-out is equal to LP-in.
10)
At system start-up: iSave can run for up to 10 min.
with 150% of max. rated flow at LP inlet. The time
where max. rated flow is exceeded should be kept
as short as possible to minimize wear.
Technical specifications
Media temperature
5)
o
C
2-35
2-35
o
F
36-95
36-95
Ambient temperature
o
C
0-50
0-50
o
F
32-122
32-122
Filtration requirements (nominal)
6)
3 micron melt-blown
Salinity increase at membrane at 40% recovery rate at
balanced flow
9)
2-3%
Weight (dry)
kg
164
164
lb
362
362
Weight (operation with water)
kg
172
172
lb
379
379
Noise
Sound pressure level L
PA
1 m
8)
dB(A)
83
86
Torque data
Max. allowable working torque
Nm
170
190
lbf-ft
125
140
Max. starting torque (stick/slip)
Nm
180
180
lbf-ft
132
132
Summary of Contents for iSave 50
Page 20: ...Operating guide iSave 50 70 20 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...
Page 23: ...Data sheet iSave Energy Recovery Device iSave 50 iSave 70 hpp danfoss com...
Page 50: ...Danfoss DCS im 2020 01 180R9213 521B1164 DKCFN PI 003 F8 02 50...
Page 51: ...Design guide Energy Recovery Device iSave Membrane cleaning of RO system hpp danfoss com...
Page 56: ...Danfoss DCS im 2017 09 521B1165 DKCFN PI 00 G6 02 56...
Page 57: ...ro solutions com Design Guide APP pumps and iSave overload protection hpp danfoss com...
Page 66: ...Danfoss DCS im 2018 08 180R9372 521B1412 DKCFN PI 003 O2 02 66...
Page 74: ...Danfoss DCS im 2019 05 180R9084 521B0540 DKCFN PI 000 D7 02 74...
Page 75: ...Parts list Energy recovery device iSave 50 70 hpp danfoss com...
Page 86: ...86 Danfoss DCS im 2021 03 180R9392_AX299849991270en 000701...
Page 87: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 91: ...91 180R9357 AQ265943679828en 001002 IOM iSave 50 70 03 2023...