© Danfoss | Climate Solutions | 2023.07
AX450533577373en-000201 | 11
4.2 Assembling the terminal board
HG8/HG88e
¾
Connect the electrical connections as per the illustration on page 12.
¾
Slightly oil the new seal.
¾
Carefully remove the residual silicone from the terminal
board without damaging the sealing surface!
NOTE HG7/HGZ7
X
At voltages below 400 V (special voltage), an intermediate plate, part no. 06908, including intermediate
seal and longer screws, must be installed.
60 Nm
HG7/HGZ7
Assembly
60 Nm