User Guide 

FP720 Two Channel Heating Timer

Danfoss Heating

 

VUSUH102

 05/2019 

3

Timer Schedule Setup

•  Press  

  button to access schedule setup

•  Press CH button to select between SET CH1 or SET HW schedule (CH1 and CH2 if set for two heating zones), 

press OK to confirm

Example below for 5/2 day setup, 2 periods

 

Mo. Tu. We. Th. Fr. flashing

Press 

OK

 to accept or right arrow to select Sa. Su.

Period 1:

1. Use 

<

 or 

>

 to select 

ON

 hour, press 

OK

 to confirm

2. Use 

<

 or 

>

 to select 

ON

 minute, press 

OK

 to confirm

3. Use 

<

 or 

>

 to select 

OFF

 hour, press 

OK

 to confirm

4. Use 

<

 or 

>

 to select 

OFF

 minute, press 

OK

 to confirm

Repeat 1 to 4 above for period 2

Sa. Su. Now showing in display.

Period 1

1. Use 

<

 or 

>

 to select 

ON

 hour, press 

OK

 to confirm

2. Use 

<

 or 

>

 to select 

ON

 minute, press 

OK

 to confirm

3. Use 

<

 or 

>

 to select 

OFF

 hour, press OK to confirm

4. Use 

<

 or 

>

 to select 

OFF

 minute, press 

OK

 to confirm

Display returns to home screen and schedule is set.

Where FP720 is set for 7 day schedule, option will be given to select each day separately.  In 24 hr mode, option 

will only be given to select Mo. to Su. together.  See parameter P1.

Where FP720 is set for 3 periods, options will be given to select period 3 times.  In 1 period mode, option will only 

be given for one time period.  See parameter P2.

A default program provides timer control if the user does not create own programs:

5/2 or 7 day – 3 Periods selected

Days

Event 1 - On

Event 2 - Off

Event 3 - On

Event 4 - Off

Event 5 - On

Event 6 - Off

Start time

Start time

Start time

Start time

Start time

Start time

Mon - Fri

6:30 

8:30

11:30

13:30

16:30

22:30

Sat - Sun

7:30

9:30

11:30

13:30

16:30

22:30

* Floor temperature control mode.

For 24hr mode, default schedule follows Mo. to Fr. times above.

For 2 periods setup, default event times 1, 2, 5 & 6 are used.  For 1 period setup, default event times 1 & 6 are 

used.

Note:

 if parameter P1 or P2 are changed schedule will default to times above and user selected times will need to be 

reset.