Instruction FH-CWD Thermostat
4
VI.CU.B2.02
Produced by Danfoss Floor Heating Hydronics 05.2011
3. Installation
Installing the Room Thermostat- fig. 5 and fig. 6
• Remove the connection cable between front and
back part.
• Connect the thermostat correctly to mains supply
according to the Wiring Diagram - fig 6.
• Mount the thermostat by using the enclosed
screws to the wall box.
• Mount the front correctly.
Wiring Diagram – fig. 6
The product must be connected to the following
leads:
• Term L:
Phase (L) AC85-250V, 50/60 Hz
• Term NO:
Valve (NO)
• Term NC:
Valve (NC)
• Term N:
Neutral (N)
• Term 2:
Empty
• Terminal S2:
Floor sensor
• Terminal S1:
Floor sensor
4. General usage
Turn ON/OFF the Room Thermostat Fig. 1
• Turn the thermostat on or off by pressing .
Summary of Contents for FH-CWD
Page 1: ...Instruction FH CWD Thermostat...
Page 16: ...www heating danfoss com...