Instruction FH-CWD Thermostat
5
Produced by Danfoss Floor Heating Hydronics 05.2011
VI.CU.B2.02
Display of Room Temperatures - fig. 3
• The actual room temperature is shown in the display
as default
.
Setting of Room Temperature Fig. 1
• Press the to set the desired room temperature
value,
is shown in the display.
• When releasing the selector the display returns
to actual room temperature
.
5. Choosing room temperature
control or both room and floor
temperature control
Turn OFF the thermostat by pressing Fig. 1
.
• Press and hold Fig. 1
for 10 seconds. The display
will show 01.
• Press Fig. 1
to adjust desired controltype.
01=room temperature control, only with room
sensor, no floor sensor, check and setting only room
temperature.
02=both room and floor temperature control, with
room sensor and floor sensor, check and setting room
temperature and maximum floor temperature limit.
Factory setting is 01.