Instruction FH-CWD Thermostat

7

Produced by Danfoss Floor Heating Hydronics 05.2011 

VI.CU.B2.02

7. Frost protection 

Using the Frost Protection Mode instead of turning 
the thermostat OFF completely may protect against 
damages due to low temperatures. The room tem-
perature will be maintained around 5 °C.

•   Turn OFF the thermostat by pressing   Fig. 1 

.

•  Press M Fig.1 

 for 3 seconds and release.

•  Select 01 (00= disabled).
If the room temperature is lower than 5 °C  the heating 
will be turned ON and     will be shown in the display.
If the room temperature is higher than 7 °C the heating 
is turned OFF.
Factory setting is 00.

8. Error messages

E1 will be displayed when room sensor failure.
E2 will be displayed when floor sensor failure. E2 
will be read when pressing 

M

 Fig. 1 

 to check floor 

temperature.
Any case, all relay output would be turned off.

Summary of Contents for FH-CWD

Page 1: ...Instruction FH CWD Thermostat...

Page 2: ...and floor temperature control 5 6 Maximum floor temperature protection 6 7 Frost protection 7 8 Error messages 7 9 Technical Specifications 8 10 Figures and illustrations 12 Index IMPORTANT Protect t...

Page 3: ...fig 2 Screw hole for flush mounting Terminals for cable mounting Symbols in the display fig 3 Room Sensor Floor Sensor Temperature indication Set Room temperature Set Floor temperature Floor heating A...

Page 4: ...supply according to the Wiring Diagram fig 6 Mount the thermostat by using the enclosed screws to the wall box Mount the front correctly Wiring Diagram fig 6 The product must be connected to the foll...

Page 5: ...play returns to actual room temperature 5 Choosing room temperature control or both room and floor temperature control Turn OFF the thermostat by pressing Fig 1 Press and hold Fig 1 for 10 seconds The...

Page 6: ...s Displaying the Floor Temperature The function allows you to check the internal tem perature of the floor Works only with floor sensor Turn ON the thermostat by pressing Fig 1 Press M Fig 1 shortly a...

Page 7: ...he thermostat by pressing Fig 1 Press M Fig 1 for 3 seconds and release Select 01 00 disabled If the room temperature is lower than 5 C the heating will be turned ON and will be shown in the display I...

Page 8: ...stment mode Push buttons Programmable No Fault indication failure mode If room sensor failure E1 will be displayed If floor sensor failor E2 will be displayed In any case thermostat will turn off all...

Page 9: ...Mounting Flush Mounting for Euro pean and Chinese built in sockets Network wire No Network wireless No Off set function Yes 10 C Power consump tion 2 W Power supply battery No Power supply net 85 250...

Page 10: ...uced by Danfoss Floor Heating Hydronics 05 2011 Feature Description Sensor floor set range 20 45 C Sensor room NTC 100K accuracy 1 Sensor room set range 5 35 C Shell material non inflammable 94V0 Yes...

Page 11: ...Instruction FH CWD Thermostat 11 Produced by Danfoss Floor Heating Hydronics 05 2011 VI CU B2 02...

Page 12: ...Instruction FH CWD Thermostat 12 VI CU B2 02 Produced by Danfoss Floor Heating Hydronics 05 2011 Fig 1 Fig 2...

Page 13: ...Instruction FH CWD Thermostat 13 Produced by Danfoss Floor Heating Hydronics 05 2011 VI CU B2 02 Fig 3 Fig 4...

Page 14: ...Instruction FH CWD Thermostat 14 VI CU B2 02 Produced by Danfoss Floor Heating Hydronics 05 2011 Fig 5 Fig 6 FH CWD L NO NC N S2 S1 Remote Floor Sensor AC85 250V 50 60 Hz...

Page 15: ...Instruction FH CWD Thermostat 15 Produced by Danfoss Floor Heating Hydronics 05 2011 VI CU B2 02...

Page 16: ...www heating danfoss com...

Reviews: