| 19
DKRCE.PI.RL0.H7.ML
Installation Guide | ERC 214
Parameter name - ERC 214
Code
Min
Max
Unit
App. 0
(Def.)
App. 1 App. 2 App. 3 App. 4 App. 5 App. 6
Display at defrost
Air=actual air temperature, FrE=freezed
temperature, -d-="-d-" is displayed
o91
Air
-d-
-d-
-d-
-d-
-d-
-d-
-d-
-d-
Polarity
P--
DI1 input polarity
nc=normally closed,
no=normally open
P73
nc
no
no
no
no
no
no
no
no
DI2 input polarity
nc=normally closed,
no=normally open
P74
nc
no
no
no
no
no
no
no
no
Invert alarm relay
0=normal, 1=invert relay action
P75
0
1
0
0
0
0
0
0
-
Keyboard lock enable
P76
no
yES
no
no
no
no
no
no
-
Readouts
u--
Controller status
S0=cooling ON/Heating ON,
S2=wait for compressor ON time to elapse,
S3=wait for compressor OFF time to elapse-
restart time, S4=drip OFF delay after defrost,
S10=cooling stop S11=cooling stopped by
thermostat/heating OFF, S14=defrosting state,
S15=fan delay state after defrost, S17=door
open (DI input), S20=emergency cooling,
S25=manual control of outputs, S30=continous
cycle/Pull-down, S32=delay of outputs at
power up
u00
S0
S32
--
Note: hidden parameters are greyed out
ENGLISH
Summary of Contents for ERC 214
Page 1: ...Installation Guide ERC 214 Digital controller for refrigeration and defrost 4 relays...
Page 64: ...64 DKRCE PI RL0 H7 ML Installation Guide ERC 214 6 DEFROST 3 DEFROST 3 DEFROST SET UP DOWN SET...
Page 148: ...148 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 149: ...149 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 150: ...150 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 151: ...151 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...