| 17
DKRCE.PI.RL0.H7.ML
Installation Guide | ERC 214
Parameter name - ERC 214
Code
Min
Max
Unit
App. 0
(Def.)
App. 1 App. 2 App. 3 App. 4 App. 5 App. 6
Defrost stop sensor
configuration
non=time, Air=Sair (air
temperature), dEF=S5 (defrost sensor)
d10
non
dEF
non
non
non
non
dEF
dEF
non
Compressor accumulated
runtime to start defrost
0=OFF
d18
0
96
hours
0
0
0
0
0
0
-
Defrost on demand
20.0=OFF
d19
0.0
20.0
K
20.0
-
-
-
20.0
20.0
-
Defrost delay after pull-down
0=OFF
d30
0
960
min
0
0
0
0
0
0
-
Fan control
F--
Fan at compressor cutout
FFc=fan follow compressor, FAo=fan always ON,
FPL= fan pulsating
F01
FFc
FPL
FAo
FAo
FAo
FAo
FAo
FAo
FAo
Fan stop evaporator temperature
50.0=OFF
F04
-50.0
50.0
C/F
50.0
-
-
-
50.0
50.0
-
Fan ON cycle
F07
0
15
min
2
2
2
2
2
2
2
Fan OFF cycle
F08
0
15.0
min
2
2
2
2
2
2
2
Compressor
c--
Compressor minimum ON time
C01
0
30
min
0
0
0
0
0
0
0
Compressor minimum OFF time
C02
0
30
min
2
2
2
2
2
2
2
Compressor OFF delay
at door open
C04
0
15
min
0
0
0
0
0
0
1
Zero crossing selection
C70
no
yES
yES
yES
yES
yES
yES
yES
yES
Others
o--
Delay of outputs
at startup
o01
0
600
min
5
5
5
5
5
5
5
DI1 configuration
oFF=not used, Sdc=status display output,
doo=door alarm with resumption, doA=door
alarm without resumption, SCH = main
switch, nig=day/ night mode, rFd=reference
displacement, EAL=external alarm, dEF=defrost,
Pud=pull-down, Sc=condenser sensor
o02
oFF
Sc
oFF
oFF
oFF
oFF
oFF
oFF
oFF
Note: hidden parameters are greyed out
ENGLISH
Summary of Contents for ERC 214
Page 1: ...Installation Guide ERC 214 Digital controller for refrigeration and defrost 4 relays...
Page 64: ...64 DKRCE PI RL0 H7 ML Installation Guide ERC 214 6 DEFROST 3 DEFROST 3 DEFROST SET UP DOWN SET...
Page 148: ...148 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 149: ...149 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 150: ...150 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...
Page 151: ...151 DKRCE PI RL0 H7 ML Installation Guide ERC 214 Notes...