Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 165
Status Signal
Time period
before
reacting
Typical Vehicle Controller Unit (VCU) Expected
Action
Recommended Service Action
MCU Turbo Mode
Section
X
Nothing, typical occurrence
X
MCU Using Raw Speed
Section
X
Nothing, typical occurrence
X
MCU Acceleration
Limited
Section
X
Nothing, typical occurrence
X
MCU Current Transducer
Fault Ileg/Ibus
Section
Long
Check engine light
Record data and contact Danfoss Power Solutions.
MCU ABC Phase Order
Section
X
Nothing, typical occurrence
X
MCU System Disabled In
Motion
Section
Short
Customer dependent - Is customer enabling the
Danfoss Power Solutions drive?
X
MCU CAN Limits Active
Section
X
Nothing, typical occurrence
X
Summary of Contents for ED-DT318B