Installation and Operation Guide
ED-DT318B
Drive Train Systems with Traction Control, Inverter/Controller, and Motor with 2 Speed Transmission
BC353060341319en-000101
Revision D
© Danfoss | November 2020 | 98
Classified as Business
lsb:
57
msb:
57
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
ADC Calibration Problem
has been set to True at some point since the last time
MCU power was cycled.
False
MCU
ADC Calibration Problem
has not been set to True at any point since the last time
MCU power was cycled.
7.3.3.9
MCU Over Voltage Alarm
dbc ref:
TCUStat3_MCUOverVoltageAlarm
lsb:
56
msb:
56
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
The High Voltage DC bus voltage is greater than the high voltage alarm threshold.
False
The High Voltage DC bus voltage is less than the high voltage alarm threshold.
If this condition is detected by the MCU, it will attempt to reduce the voltage by switching to the
Forced Voltage Control mode and severely limiting the available regeneration torque.
7.3.3.10
MCU Over Voltage Alarm History
dbc ref:
TCUStat3_MCUOverVoltageAlarmHistory
lsb:
55
msb:
55
Offset:
0
Scale Factor: 1
Min Value:
0
Max Value:
1
Units:
Boolean
Description: True
MCU
Over Voltage Alarm
has been set to True at some point since the last time MCU
power was cycled.