Installation Instruction
Danfoss Self-limiting Heating Cables
088L8008 / VIAMQ502
8 | © Danfoss | FEC | 2019.02
2
Installation in General
2.1
Fastening Methods
Danfoss Aluminium Tape
For ensuring efficient heat transfer.
Spaceclip
For attaching cables and relieving from sharp edges.
2.2
Calculating C-C Distance
For areas on roofs the C-C distance is the distance in
centimetres from the centre of one cable to the
centre of the next.
C-C = Area [m²] x 100 cm
Cable length [m]
C-C = Cable output [W/m] x 100 cm
Heat density [W/m²]
The max. C-C distance for roof and gutter systems is
10 cm.
W/m² @ 220 V
C-C [cm]
20 W/m
25 W/m
30 W/m
5
366
457
-
7,5
244
305
366
10
183
229
274
W/m² @ 230 V
C-C [cm]
20 W/m
25 W/m
30 W/m
5
400
500
-
7,5
267
333
400
10
200
250
300
W/m² @ 240 V
C-C [cm]
20 W/m
25 W/m
30 W/m
5
436
544
-
7,5
290
363
436
10
218
272
327
ECiceguard 18
C-C [cm]
220 V
230 V
240 V
5
329 W/m²
360 W/m²
392 W/m²
7,5
219 W/m²
240 W/m²
262 W/m²
10
165 W/m²
180 W/m²
196 W/m²