TEMP-SET
Displaying the error code and water temperature setting alternatively.
If the system is in ECONOMY mode and a malfunction occurs, the system can still be operational by switching to E-
HEATER mode, even though it could not reach the expected efficiency. Contact your supplier for help.
DANGER! The heat pump cover must only be opened by authorised service technicians.
Table 4.
Error Codes
Error
code
Description
Error
code
Description
E0
Error of sensor T5U
P1
System high pressure protection
E1
Error of sensor T5L
P2
Discharge pipe high temperature protection
E2
Tank and Wired Controller communica-
tion error
P3
Compressor not running
E4
Evaporator pipe temperature sensor error P4
Compressor overload protection
E5
Ambient temperature sensor error
P8
Malfunction of electrical heater
E6
Discharge pipe temperature sensor error
P9
E-heater overload protection
E7
System error
E8
Electrical leakage protection
E9
TH sensor condenser failure
LA
Ambient temperature is not fit for heat
pumps. Change mode to E-heater mode
to continue operation.
If any of the above error codes occur, call for service.
11.4
Operating Capability
11.4.1
Water heating operating capability
The following heating elements are included in the unit,
•
A heat pump
•
An electrical heater
•
A solar coil
These three heating elements cannot work together simultaneously.
The unit has two tank temperature sensors, one is installed at the upper part of the tank (35) and the other at the
Installation, Service and User Manual VMGFK202 – 29