Menu selection
Meaning
Factory setting
AUX. HEAT 3
0 = stop aux. heater step 3
1 = start aux. heater step 3
EXT.AUX.HEATER
0 = stop external auxiliary heater
1 = start external auxiliary heater
EXT.CIRC. PUMP
0 = stop circulation pump
1 = start circulation pump
SHUNT DEFR
- = opens flow from defrosting tank
0 = shunt unaffected
+ = closes flow from defrosting tank
FAN L
0 = stop fan
1 = start fan at low speed
FAN H
0 = stop fan
1 = start fan at high speed
EXT. AUX. HEATER
0 = 0V on plinth 283
1 = control voltage 230V on plinth 283
ALARM
0 = stop signal on output External alarm
1 = start signal on output External alarm
-
SHUNT COOLING
- = closes shunt
0 = shunt unaffected
+ = opens shunt
-
SHUNT GROUP
- = closes shunt
0 = shunt unaffected
+ = opens shunt
2ND H.C SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
Only at buffer tank
PASSIVE COOLING
0= stop passive cooling
1= start passive cooling
COOLING A
0= stop active cooling
1= start active cooling
REV. V. POOL
0 = normal mode for the exchange valve
1 = pool mode for the exchange valve
-
0-10V
Used for circulation pumps at BUFFER TANK.
-
34 – Installation instructions