Menu selection
Meaning
Factory setting
REV.V. HOT WATER
Indicates
whether the
exchange
valve for hot
water is loca-
ted before or
after the
external auxil-
iary heater.
(Determines
whether the
external auxil-
iary heater
may produce
hot water.)
INT / EXT
TOPH. AUX
Indicates
whether the
external auxil-
iary heater
can be used
for anti-
legionella.
OFF / ON
11.1.4
Sub menu MANUAL TEST
Table 11.
Used to manually test and test operate the heat pump’s components or signal outputs.
Menu selection
Meaning
Factory setting
MANUAL TEST
0 = deactivate manual test
1 = activate manual test
2 = activate manual test with option of navigating from the SERVICE menu to
check that the temperatures rise for example.
-
HEAT PUMP
0 = stop heat pump
1 = start heat pump
Note! The heat pump cannot be started in the event of an
active alarm.
-
BRINE PUMP
0 = stop the brine pump
1 = start the brine pump
-
CIRC. PUMP
0 = stop the circulation pump
1 = start the circulation pump
-
REV.V. HOT WATER
0 = heating mode for the exchange valve
1 = hot water mode for the exchange valve
-
SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
SYSTEM SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
Only at buffer tank
HGW-SHUNT
- = closes shunt
0 = shunt unaffected
+ = opens shunt
AUX. HEAT 1
0 = stop aux. heater step 1
1 = start aux. heater step 1
-
AUX. HEAT 2
0 = stop aux. heater step 2
1 = start aux. heater step 2
Installation instructions
VMIFJ102
– 33