10 – Appendix UK
3.2.2
Unvented package installation, DHP-L models, DWH 200, DWH 300
DHP-L
126
110
80
128
96
80
104
80
129
132
Unvented manifold assembly
(see figure 1)
DWH 200
DWH 300
96
10 11
13
12
12
86
91
113
Figure 4.
The principal installation solution of the unvented package on DHP-L models together with DWH.
Position Name
10
Supply line heating system
11
Return line heating system
12
Cold water
13
Hot water
80
Shut-off valve
86
Safety relief valve heating system
91
Strainer
96
Flexible hose
104
Safety relief valve 2,5 bar
110
Expansion vessel
113
Expansion heating system
126
Factory fitted combined Temperature and pressure relief valve*
128
Double check valve with Shut-off valve
129
Unvented manifold assembly: Pressure reducing valve, Safety relief valve, Non-return valve
132
Flexible hose unvented package
*
) The water heater tank in DWH is factory fitted with a Temperature and pressure relief valve . The connec-
tion from this valve must not be used for other purposes other than discharge pipe connection . Please see
chapter 5 .3 Discharge pipe arrangement .
DD
E D
Note! No valve should be fitted between the safety relief valve and the storage cylinder .
Summary of Contents for DHP-A
Page 15: ...Appendix UK 15...