Appendix UK – 7
2.1.4
Additional label: DHP-AQ Control Maxi 6–13 SP
This label will ensure that this product conforms to the requirements
of United Kingdom Building Regulations and EN12897:2006.
The information is entirely valid in a UK specific installation.
Weight when full
286 kg
PT valve replacement no.
086U8267
Oper. temp non self-reset. thermostat
88˚C
Maximum flow temperature
65˚C
Operating pressure heat source
1 bar
Primary heating power input
9 kW
Primary flow rate
0,16−0,31 l/s
Actual capacity
180 liter
Standing heat loss
1,8 kWh / 24 h
Maximum water supply pressure
10 bar
Pressure reducing valve
3 bar
Expansion valve
6 bar
Expansion vessel charge pressure
3 bar
Operating pressure
5,5 bar
Temp and pressure release valve
10 bar; 90−95˚C
Maximum primary working pressure
1,5 bar
Immersion heater
D76 / 9 kW / 230 V
WARNING TO THE USER
a) Do not remove or adjust any component part of this
unvented water heater. Contact the installer.
b) If this unvented water heater develops a fault, such as a flow
of hot water from the discharge pipe,
switch the heater off and contact the installer.
WARNING TO THE INSTALLER
a) This installation is subject to Building Regulations notification.
b) Use only appropriate components for installation and maintenance.
c) INSTALLED BY:
Name.______________________________________
Address.____________________________________
Tel No._____________________________________
Completion date._____________________________
Summary of Contents for DHP-A
Page 15: ...Appendix UK 15...