15
INSTALLATION GUIDE
DEVIreg™ Room
Technical specifications
Operating voltage
220-240 V~, 50/60 Hz
Power consumption
OFF: <175 mW
Idle: <200 mW
Contact rating:
- Resistive load
- Inductive load
230 V ~ 16 A/3680 W
Cos φ = 0,3 max. 1 A
Floor sensor
NTC 15 kΩ @ 25 °C, 3 m. (default)*
Control
PWM (Pulse Width Modulation)
Temperature control
range
Room temperature: 15 °C to 35 °C
Floor temperature: 5 °C to 35 °C
(45 °C after breakout)
Ambient temperature range 0 °C to 35 °C
Frost protection
4 °C to 14 °C (default value 5 °C)
IP class
21
Protection class
Class II -
Maximum cable size
1 x 4 mm2 or 2 x 2,5 mm2 /terminal
Controller type
1B
Software class
A
Pollution degree
2 (Domestic use)
Over voltage category
III