Page 1: ...Installation Guide DEVIreg Room Intelligent electronic timer controlled thermostat with App control EN...
Page 2: ......
Page 3: ...ble of contents 1 Introduction 4 2 Standard Compliance 5 3 Safety instruction 6 4 Installation Guidelines 7 5 User Guide 17 DEVI Control App 25 DEVI Control App User Guide 25 6 Eco Design Sheet 29 7 W...
Page 4: ...sed for control of total heating as well as comfort heating of the room The thermostat supports a selection of commonly used frame systems for 55x55 inner geometry framing systems Among others the the...
Page 5: ...thermostat EN 301 349 1 and EN 301 349 17 EMC standard for radio equipment operating in the 2 4 GHz band EN 300 328 Efficient use of radio spectrum for radio equipment operating in the 2 4 GHz band SI...
Page 6: ...mendations Electrical heating thermostats must always be installed according to local building regulations and wiring rules Installation must be carried out by an authorized and or qualified installer...
Page 7: ...at are present on our YouTube channel 4 Installation Guidelines Follow these guidelines when placing the thermostat Install the thermostat in a suitable height on the wall typical 80 170 cm Do not pla...
Page 8: ...ostat must not be installed in direct wet areas Zones 0 1 and 2 Always follow local regulations regarding IP classes this doesn t mean that the thermostats can t be installed in bathrooms Do not posit...
Page 9: ...pc Frame 1 pc Frame adapter 1 pc Spacer and 1 pc wire sensor along with the instructions written in local official language 2 Place the floor sensor in the Flexpipe and make sure the sensor element is...
Page 10: ...m located at a representative position 5 For thin floor constructions the Flexpipe should be flush with the sub floor surface countersink the Flexpipe if possible For thicker constructions the Flexpip...
Page 11: ...ll pole disconnect 7 Connect the wires according to the wiring diagram on back of the power supply of the thermostat Ensure that the terminals are properly fastened and wires are securely connected 8...
Page 12: ...ing to the arrow 10 Attach the frame and the Top frame to the thermostat After that attach the thermostat to the Power supply unit by a softly press until all parts firmly connected 11 Carefully attac...
Page 13: ...stat does not require any settings to be performed in the app however this will be required to modify advanced features schedules and more 14 Dismount thermostat front for replacement Perform steps 11...
Page 14: ...14 INSTALLATION GUIDE DEVIreg Room Connection scheme DEVIreg Room Room t sensor Load max 16 A NTC 15 kOhm at 25 C sensor adaptation possible...
Page 15: ...15 k 25 C 3 m default Control PWM Pulse Width Modulation Temperature control range Room temperature 15 C to 35 C Floor temperature 5 C to 35 C 45 C after breakout Ambient temperature range 0 C to 35...
Page 16: ...Ball pressure test 75 C Storage temperature 25 C to 60 C Timer functions 3 periods per day Resolution of timer is 30 minutes Timer backup for 1 hour Dimensions 85 mm x 85 mm x 20 24 mm in wall depth 2...
Page 17: ...N GUIDE DEVIreg Room 5 User Guide Product interface Temperature adjustment Indicator OFF Timer schedule App communication Frost protection Whenknobisintempadjustmentmodethethermostatwillnotrunthetimes...
Page 18: ...t By turning the knob clockwise the temperature will increase User interface daily use On the thermostat the temperature can be directly adjusted using the knob dial by setting the indicator on the wa...
Page 19: ...ule App communication the app can only display limited information in OFF the app and thermostat will be completely OFF and nothing will be indicated or communicated to the app To pair the thermostat...
Page 20: ...oduct these will light up when needed Indicators inside the knob All indicators fade out after a duration default 20 seconds unless an error is present Additionally indicators will wake up upon manual...
Page 21: ...he indicator fades out The indicator flashes red when an error is present this will persist until error is alleviated heating will not be activated activatable Data communication This indicator flashe...
Page 22: ...The warning will be present until App communication is activated however the indicator will only flash for a duration default 20 seconds Warnings will be displayed in the App Default settings and out...
Page 23: ...rform a factory reset All indicators will flash briefly to inform about successful factory reset The thermostat will briefly be rebooting please allow for up to 5 seconds for the thermostat to be back...
Page 24: ...mode needs to be set in the app after the action has been performed To best perform the action the thermostat unit needs to be dismounted from the power supply on the back of the thermostat there is...
Page 25: ...p initiate the app and follow the instructions provided in the app App enabled functions wizard assisted installation scheduling pre heating adaptive heating thermostat limits adaptation control mode...
Page 26: ...ock is enable and the user tries to change the setpoint or mode with the potentiometer or encoder W5 Set temperature not achievable Warning given when the room floor temperature from schedule or manua...
Page 27: ...act installer or local Danfoss service The thermostat requires a restart to operate again Thermostat overheated E3 Thermostat is overheat ed heating is turned off Wait until thermostat cools down The...
Page 28: ...etected as defective Contact installer or local Danfoss service The potentiometer is reading a value that is outside of the given range Invalid com munication E10 Bluetooth communi cation error Retry...
Page 29: ...duct is prefilled please fill any all blank slots Information requirements for electric local space heaters Model identifier s DEVIreg Room Item Sym bol Value Unit Item Unit Heat output Type of heat i...
Page 30: ...consumption fan assisted heat output yes no At nominal heat output elmax 0 00062 kW Type of heat output room temperature control select one At minimum heat output elmin 0 00062 kW single stage heat ou...
Page 31: ...ol no electronic room temperature control plus day timer no electronic room temperature control plus week timer yes Other control options multiple selections possible room temperature control with pre...
Page 32: ...TION GUIDE DEVIreg Room with distance control option no with adaptive start control yes with working time limitation no with black bulb sensor no Contact details Danfoss A S Nordborgvej 81 6430 Nordbo...
Page 33: ...arranty period Danfoss shall offer a new comparable product or repair the product if the product is found to be faulty by reason of defective design materials or workmanship The decision to either rep...
Page 34: ...hase documents invoice receipt or similar during the whole warranty period DEVIwarranty shall not cover any damage caused by incorrect conditions of use incorrect installation or if installation has b...
Page 35: ...EVIreg Room WARRANTY CERTIFICATE The DEVIwarranty is granted to Address Stamp Purchase date Serial number of the product Product Art No Connected output W Installation Date Signature Connection Date S...
Page 36: ...at it may not be disposed of as household waste It must be handed over to the applicable take back scheme for the recycling of electrical and electronic equipment Dispose of the product through channe...
Page 37: ...37 INSTALLATION GUIDE DEVIreg Room...
Page 38: ...38 INSTALLATION GUIDE DEVIreg Room...
Page 39: ...140R0040 AN461038960054en 010103 Produced by Danfoss 2023 11 INSTALLATION GUIDE DEVIreg Room Danfoss A S Nordborgvej 81 6430 Nordborg Denmark...
Page 40: ...140F1161 DEVIreg Room Room thermostat 220 240V Load 16 A 3680 W 230V 50 60Hz 0T35 C IP21 MADE IN MALAYSIA Designed in Danmark 5 703466 250389 Danfoss Ltd 22 Wycombe End HP9 1NB GB 140R0040...