INSTALLATION GUIDE
DEVIreg™ Room
Warnings and error messages
Warning table
Warning
Description
Reference
W1
Schedule
overwritten due
to manual dial
setting
Set when Schedule is active (Set in App)
but dial has been turned to set a manual
setpoint
W2
Invalid clock
If time is totally invalid - less than 2021 or
above 2050 or use production date or first
time connected to App
W3
Child lock is
enable
Will be active if child lock is enable and
the user tries to change the setpoint
or mode with the potentiometer (or
encoder)
W5
Set temperature
not achievable
Warning given when the room/floor
temperature from schedule or manual
setpoint can’t be reached within 40 PWM
periods (Output from heating control)
W8
Maximum Floor
Temperature Limit
reached
Set if Maximum Floor Temperature is
reached while in Combi Mode while
Room Temperature is not at Set point
W10
Temperature set
above maximum
temperature limit
Set, if maximum temperature is lower than
the current temperature knob/potentiometer
is pointing at. Like Max set to 25°C and knob
is set to 27°C