background image

6.2.5. Plant Name

The  plant  name  is  displayed  on  the  main  page  of  the  Danfoss  SolarApp.  This  name  can  be
changed to a user-defined name of maximum 30 characters. Special characters and spaces can
be used.

6.2.6. CO

2

 Emission

The  default  value  used  for  calculation  of  saved  CO

2

  is  0.5  Kg  per  kWh.  This  value  can  be

changed via [Settings 

 CO

2

 emission].

6.2.7. Revenue

To change the currency and the 'Price per kWh', navigate to [Settings 

 Revenue]. Currently

Euro, DKK, USD and GBP are supported.

6.2.8. Configuring Date and Time

When connected to the internet, no changes to 'date and time' are required. When used with-
out internet connection, 'date and time' must be set manually in order to ensure correct data
logging.

6.2.9. Language

On the settings page, the applications for current language can be set.

6.2.10. About

The serial number and MAC address together with software and hardware versions of the CLX
box are displayed here.

6. Configuration

20

 

 L00410601-06_5b 

 

6

Summary of Contents for CLX Series

Page 1: ...Danfoss CLX Series Quick Guide Kurzanleitung CLX Home GM CLX Standard GM CLX Standard MAKING MODERN LIVING POSSIBLE SOLAR INVERTERS...

Page 2: ...Choice of Language Sprachauswahl Page 2 English UK Seite 26 Deutsch L00410601 06_5b 1...

Page 3: ...5 Getting Started 13 Getting Started 13 Registering the CLX Box on the CLX Portal 13 Installing the Danfoss SolarApp 14 System Requirements 14 Installation on Smartphone or Tablet 14 Browser Plugin In...

Page 4: ...7 Application and Data 21 Main Page 21 Production Graphs 22 Logging Capacity 23 Logging Interval 23 Plant Status 23 Detailed Inverter Data 24 8 Technical Data 25 Contents L00410601 06_5b 3...

Page 5: ...lowing symbols The Attention symbol draws attention to a risk of damage to components or danger to persons if the information provided is not observed This type of infor mation must be observed at all...

Page 6: ...m service Equipment must only be operated at the rated supply voltages A suitable power supply unit is included in the scope of delivery Note Observe the manufacturer s instructions regarding the hand...

Page 7: ...ction First Use of the Danfoss SolarApp CLX Home GM and CLX Standard GM In addition to the functionality provided by the CLX Standard variant the CLX Home GM and CLX Standard GM provide the interface...

Page 8: ...TP10 100 cat 5e termination plugs for terminating the RS 485 inverter network Packaging Instructions 2 2 System Requirements 2 2 1 Intended Use The CLX Series is intended solely for use with Danfoss...

Page 9: ...2 Ethernet port for LAN 3 Easylan for connecting a Sensor Interface box 4 Input terminals 12 lines 2 x voltage 4 x relay input S01 S02 S03 S04 2 x analogue input 4 20 mA A1 A2 5 6 RS 485 for connecti...

Page 10: ...n 3 Up 4 Confirm 3 3 Micro SD Card The micro SD card is used for storage of events and inverter data The CLX box is only partly functional without the micro SD card Note The micro SD memory card must...

Page 11: ...t ensure free access for cable connections from below Use cable an chors for strain relief Like all electronic equipment all products in the CLX Series must be protected from humidity in particular co...

Page 12: ...ons To avoid damage to any product of the CLX Series and the ripple control receiver the connection must only be made by an authorised and suitably trained electri cian Note Further information on how...

Page 13: ...cat 5e STP network cable is required connect the inverter to the free RJ 45 socket of the CLX box 5 If more than one inverter must be connected connect the inverters in an RS 485 daisy chain dependin...

Page 14: ...t on your internet router Note Detailed configuration of power management is done via the grid management menu of the web interface Note Network settings Dynamic IP address DHCP This requires a DHCP s...

Page 15: ...ws Mac OS X and Linux Internet Explorer Min version 9 Firefox Min version 9 Table 5 1 System Requirements 5 2 2 Installation on Smartphone or Tablet 1 Download the Danfoss SolarApp from Google Play fo...

Page 16: ...t serialnumber clx danfoss com in the address line of the browser The serial number is in a format where the first 8 digits are the HW version of the CLX Series and each CLX box has a different HW ver...

Page 17: ...ion email will come 3 4 Click on the link in the verification email and sign in 4 The main page of the Danfoss SolarApp opens If not see Configuration Trouble shooting for help 5 Getting Started 16 L0...

Page 18: ...e main page of the current CLX box appears At the same time the CLX box is configured for re mote access by the current user Other users may be added as described in the section Set tings Granting Rem...

Page 19: ...o configured the CLX box for initial use is always added automatically to the remote access list As default remote access is enabled To grant remote access to another user proceed as follows 1 Navigat...

Page 20: ...disable remote access select Remote access to Off setting see illustration Access Control List Note When the Access Control List is empty or when remote access is Off the CLX product is only reachable...

Page 21: ...currency and the Price per kWh navigate to Settings Revenue Currently Euro DKK USD and GBP are supported 6 2 8 Configuring Date and Time When connected to the internet no changes to date and time are...

Page 22: ...ngs sections From the main page navigate to pages with more detailed information by clicking on the indi vidual circles and links Click on View production large circle to the left to see graphs with p...

Page 23: ...ser navigation arrows will appear Illustration 7 2 Daily Production Monthly and yearly graphs are available by clicking on the buttons in the bottom area of the page By touching and holding the graph...

Page 24: ...box logs detailed inverter data every 10 min The detailed inverter data is uploaded hourly to the CLX Portal when enabled The logging interval and the upload interval cannot be changed 7 2 3 Plant Sta...

Page 25: ...de of operation of the inverter Latest event When an inverter event is present it is shown here Grid voltage for each phase V Present grid voltage measured by the inverter For each phase number of pha...

Page 26: ...ation for ex ternal floating contact 2 x 4 20 mA input analogue input without galvanic isolation Enclosure 2 part fanless metal enclosure for rail mounting IP20 DIN rail Weight 330 g net without acces...

Page 27: ...ritte 37 Erste Schritte 37 Registrierung der CLX Box im CLX Portal 37 Installieren der Danfoss SolarApp 38 Systemanforderungen 38 Installation auf Smartphone oder Tablet 38 Installation des Browser Pl...

Page 28: ...g und Daten 45 Hauptseite 45 Auswertungen 46 Protokollierkapazit t 47 Protokoll Zeitintervall 47 Anlagenstatus 47 Detaillierte Wechselrichterdaten 48 8 Technische Daten 49 Inhaltsverzeichnis L00410601...

Page 29: ...ol Achtung wird ein Sachverhalt aufgef hrt dessen Nichtbeach tung zur Besch digung von Bauteilen oder zur Gef hrdung von Personen f hren kann Die so gekennzeichneten Informationen sind unbedingt zu be...

Page 30: ...sonal durchgef hrt wer den Die Ger te sind nur mit den jeweils ausgewiesenen Versorgungsnennspannungen zu betreiben Ein geeignetes Netzteil ist im Lieferumfang des Ger tes enthalten Anmerkung Die Hers...

Page 31: ...und zeit und standortunabh ngigen Echtzeit berwachung Weitere Informationen zur Verwendung der Danfoss SolarApp in Verbindung mit der CLX Series finden Sie im Abschnitt Erste Verwendung der Danfoss S...

Page 32: ...GM CLX Standard GM oder CLX Standard mit vorinstallierter Micro SD Kar te Montageadapter mit Schraubenset Zubeh r Stromversorgung Crossover Netzwerkkabel RJ 45 TP10 100 cat 5e Ab schlussstecker zur T...

Page 33: ...LAN 3 Easylan zum Anschluss einer Sensor Interface Box 4 Eingangsklemmen 12 Anschl sse 2 x Spannung 4 x Relais Eingang S01 S02 S03 S04 2 x Analogeingang 4 20 mA A1 A2 5 6 RS 485 zur Herstellung einer...

Page 34: ...SD Karte Die Micro SD Karte dient zur Speicherung von Ereignissen und Wechselrichterdaten Die CLX Box ist ohne die Micro SD Karte nur teilweise funktionsf hig Anmerkung Die installierte Micro SD Spei...

Page 35: ...achten dass der Anschluss der Kabel jederzeit problemlos m glich ist und von unten zugef hrt werden kann Zugentlastungen vorsehen Wie alle elektronischen Ger te m ssen alle Produkte der CLX Serie vor...

Page 36: ...n einem der Produkte der CLX Serie oder dem Rundsteuer empf nger zu vermeiden darf der Anschluss nur von einem autorisierten und aus gebildeten Elektriker erfolgen Anmerkung Weitere Informationen zur...

Page 37: ...destens ein Cat 5e STP Netzwerkkabel ben tigt an die freie RJ 45 Buchse der CLX Box an 5 Wenn mehr als ein Wechselrichter angeschlossen werden muss schlie en Sie die Wechselrichter in RS 485 Reihensch...

Page 38: ...uss der LAN Schnittstelle Ihrer CLX Box an einen freien Port Ihres Internet Routers Anmerkung Die detaillierte Konfiguration der Leistungsvorgabe erfolgt ber das Netzverwaltungs Men der Web Schnittste...

Page 39: ...r Mind Version 9 Firefox Mind Version 9 Tabelle 5 1 Systemanforderungen 5 2 2 Installation auf Smartphone oder Tablet 1 Laden Sie die Danfoss SolarApp von Google Play vormals Android Market oder aus d...

Page 40: ...Erstellung eines Kontos die Adresse der PV Anlage serialnumber clx danfoss com in die Adresszeile des Browsers ein Die Seriennummer hat ein Format in dem die ersten 8 Zeichen der HW Version der CLX Se...

Page 41: ...count Konto erstellen 3 3 Sie erhalten eine Best tigungs E Mail 3 4 Klicken Sie auf den Link in der Best tigungs E Mail und melden Sie sich an 4 Die Hauptseite der Danfoss SolarApp wird ge ffnet Ander...

Page 42: ...die verf gbare CLX Box steht roter Pfeil in der Abbil dung wird die Hauptseite der aktuellen CLX Box angezeigt Gleichzeitig wird die CLX Box f r den Fernzugriff durch den aktuellen Benutzer konfigurie...

Page 43: ...Konfigurationsoptionen werden nachfolgend ausf hrlich beschrieben Abbildung 6 2 Einstellungen 6 2 1 Gew hren von Fernzugriff Der Fernzugriff auf die CLX Box wird ber eine Zugriffskontrollliste gesteu...

Page 44: ...r Zugriffskontrollliste Gehen Sie folgenderma en vor um einen Benutzer aus der Zugriffskontrollliste zu l schen 1 W hlen Sie den zu l schenden Benutzer in der Zugriffskontrollliste aus 2 Ein Bildschir...

Page 45: ...chen und Leerzeichen d rfen verwendet werden 6 2 6 CO2 Emission Der Standardwert f r die Berechnung des eingesparten CO2 ist 0 5 kg pro kWh Dieser Wert kann unter Einstellungen CO2 Emission ge ndert...

Page 46: ...erdefinierbarem Anlagennamen und den aktuellen Einstellungen f r Datum und Uhrzeit Informationen zur Konfiguration finden Sie im Abschnitt Einstellungen Von der Hauptseite aus k nnen Sie zu Seiten mit...

Page 47: ...zeigt Leis tung gegen ber Stunden am Tag Streichen Sie ber das Diagramm um die Energieerzeugung verschiedener Tage anzuzeigen Bei Verwendung der Danfoss SolarApp auf einem Tablet oder ber einen Intern...

Page 48: ...detaillierte Wechselrichterdaten Die detaillierten Wechselrichterdaten werden in das CLX Portal hochgeladen sofern aktiviert Protokoll Zeitintervall und Uploadintervall k nnen nicht ge ndert werden 7...

Page 49: ...ige Energieerzeugung Betriebsart Die aktuelle Betriebsart des Wechselrichters Letztes Ereignis Sofern ein Wechselrichterereignis existiert wird es hier ange zeigt Netzspannung f r jede Pha se V Vom We...

Page 50: ...r externen potenzialfreien Kontakt 2 x 4 20 mA Input Analogeingang ohne galvanische Trennung Geh use 2 teiliges l fterloses Metallgeh use f r Tragschienenmontage IP20 Tragschiene Gewicht 330 g netto o...

Page 51: ...errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations...

Reviews: