Instruction | APP W HC 15 - 30 pumps
39
180R9410 | AQ282628894589en-000801 | IOM APP W HC 15-30 Pumps | 01.2022
1 .
Flush inlet line before connecting the
pump, to remove possible impurities from
pipes, hoses etc .
2 .
Connect pump inlet to inlet line and flush
the pump for 5 min . by means of the
internal flushing valve, to remove possible
impurities from pipes, hoses etc .
3 .
Loosen top bleeding plug “C” (see item 3 .5)
using an allen key (only plugs with internal
hexagan sockets) . Retighten the plug, when
water APP W HC appears from the bleeding
plug .
4 .
Make sure that the direction of rotation of
the electric motor corresponds to the direc-
tion of rotation of the pump (see label on
pump) .
5 .
Now the pump is ready for start-up .
WARNING
Make sure that the direction of rotation of the
electric motor corresponds to the direction of
rotation of the pump (see label on pump).
Otherwise the pump will be damaged if a
check valve is placed between pump and feed
pump.
4.
Initial start-up
O
I
Internal
flushing
valve
5. Operation
5.1 Temperature
Fluid temperature:
Min . +2°C to max . +50°C
(Min . +35 .6°F to max . +122°F)
Ambient temperature:
Min . +2°C to max . +50°C
(Min . +35 .6°F to max . +122°F)
In case of lower operating temperatures, please
contact Danfoss High Pressure Pumps .
The chart below illustrates the corrosive
resistance of different types of stainless steel
related to NaCl concentration and temperature .
The APP W HC water pump is made of Duplex
and Super Duplex .
If the water pump is operated above the Super
Duplex line, always flush water pump with fresh
water at operation stop in order to minimize the
risk of crevice corrosion .
NaCl vs. temperature
316L
Super Duplex
80 º
C
70
60
50
40
30
20
100
160
1600
1000
16000
10 000
160000
100 000
CI -
ppm
NaCI
ppm
Duplex
Summary of Contents for APP W HC Series
Page 32: ...Danfoss DCS im 10 2019 AI283147317727en 000601 32...
Page 42: ...Danfoss DCS im 2019 10 AN283148361728en 000402 42...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 47: ...47 180R9410 AQ282628894589en 000801 IOM APP W HC 15 30 Pumps 01 2022...
Page 52: ...Danfoss DCS im 2021 09 AX283334052821en 000301 52...
Page 60: ...Danfoss DCS im 2018 11 AX283149261730en 000301 60...
Page 61: ...Service guide Trouble shooting guide APP APP S and APP S 674 pumps ro solutions com...
Page 72: ...Danfoss DCS im 2017 04 521B1447 DKCFN PZ 003 A1 02 72...
Page 79: ......
Page 80: ...Danfoss DCS im 2022 01 180R9410 AQ2282628894589 en 000801 IOM APP W HC 15 30 Pumps 80...