Instruction | APP W HC 15-30 pumps
38
180R9410 | AQ282628894589en-000801 | IOM APP W HC 15-30 Pumps | 01.2022
The valve outlet must not be connected directly to the pump suction line.
It must be connected directly to the drain.
Inlet
Outlet
Inlet
Outlet
3.5 Connections
I
C
D
O
C
C
C
I:
Inlet
O: Outlet
C: Bleeding
D:
Parallel key
For more details on the accessories,
please contact Danfoss High Pressure Pumps .
Possible extension see next page .
Accessories
Type
Code no.
3” inlet hose kit - 2m (79”)
3
”
Victaulic
180Z0144
2½” outlet high pressure hose 120 bar
2 1/2” Victaulic 1 m
Style 77DX
1)
180Z1009
2½” outlet high pressure hose 120 bar
2 1/2” Victaulic 1 .78 m
Style 77DX
1)
180Z1008
3” inlet connector
M60 - 3” Victaulic
180B3208
Non-return valve (outlet) Super Duplex
M60 - 2 1/2” Victaulic
Style 77DX
1)
180H0055
Description
APP W HC 15 - 30
E
Parallel key,
DIN 6885
mm
12 × 8 × 70
in
0 .47 × 0 .31 × 2 .76
F
Bleeding
G ¼”, Hexagon AF = 6 mm
I
Inlet port
M60 x 1 .5; depth 24 mm
O Outlet port
M60 x 1 .5; depth 24 mm
Mounting flange
ISO 3019-2 180B4TW
1)
The installation instuction for Style 77DX is located in the Victaulic document
I-100 Field Installation Handbook (htpp://static .victaulic .com)
Summary of Contents for APP W HC Series
Page 32: ...Danfoss DCS im 10 2019 AI283147317727en 000601 32...
Page 42: ...Danfoss DCS im 2019 10 AN283148361728en 000402 42...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 47: ...47 180R9410 AQ282628894589en 000801 IOM APP W HC 15 30 Pumps 01 2022...
Page 52: ...Danfoss DCS im 2021 09 AX283334052821en 000301 52...
Page 60: ...Danfoss DCS im 2018 11 AX283149261730en 000301 60...
Page 61: ...Service guide Trouble shooting guide APP APP S and APP S 674 pumps ro solutions com...
Page 72: ...Danfoss DCS im 2017 04 521B1447 DKCFN PZ 003 A1 02 72...
Page 79: ......
Page 80: ...Danfoss DCS im 2022 01 180R9410 AQ2282628894589 en 000801 IOM APP W HC 15 30 Pumps 80...