Cause
Remedy
Comments
2.1 Wear on pump
Large internal leakage due to:
-
2 .1 .1 Dismantle the pump .
2 .1 .2 Check valve plate .
Valve plate has marks/scratches on the
surface facing the port plate . Minor wear
on valve plate can cause large internal
leakage . See Index 6 .1 .
2 .1 .3 Check port plate .
Port plate has marks/scratches on the
surface facing the valve plate . Minor wear
on port plate can cause large internal
leakage . See Index 6 .2 .
2 .1 .4 Check cylinder barrel .
Liners in cylinder barrel may be scratched
or worn . Insert a piston in the liner and
check the fit . If there is any space
(clearance) between liner and piston, liner
or piston is worn .
2 .1 .5 Pre-treatment
Analyse fluid for content of particles .
- Check that filters are OK and working
correctly .
2 .1 .6 Main filtration
Check that the correct filter type is used
(particles in fluid must not exceed 10 μm) .
Danfoss High Pressure Pumps supplies
filters, please contact the sales office .
2 .1 .7 Fluid type
The APP, APP S and APP S 674 pumps are
designed for seawater operation; for any
other fluid, please contact Danfoss High
Pressure Pumps sales office for further help .
2 .1 .8 High fluid temperature
If fluid temperature is above 50 °C (122 ° F),
stop the pump immediately .
- Check internal parts (see above) .
Typical signs of wear:
Polished surface all over the swash plate .
Normally, only half of the swash plate = the
pressure side is polished . See index 6 .3 .
If the ring is missing, the piston is very worn .
The filters can be bypassed, even if they are
correctly mounted . Some filters can create
channelling where particles can pass through
the filter in tunnels . String wounded filters are
typically channelling filters . A string wounded
filter may have a filtration efficiency of only
50%, which will cause internal wear and
must
always be followed by a main filter
.
Insufficient filtration means that too many or
too large hard particles can pass the main filter
because it is damaged, bypassed or simply too
poor . Filtration efficiency must be 99 .98%
(Beta = 5000) at 10 μm to prevent abnormal
wear of the pump .
Temperature > 50 °C (122 ° F) will cause wear on
internal pump parts . Mount a temperature
switch and check its set point / function . The
temperature switch will ensure that the pump
stops at fluid temperatures > 50 °C (122 ° F) .
2.2 Low inlet pressure
2 .2 .1 Check that booster pump supplies the
right pressure/flow .
2 .2 .2 Check if filters require replacement .
If the pressure drop across the filters is too high,
the booster pump does not deliver sufficient
flow/pressure . No pressure or low pressure
results in cavitation and insufficient internal
lubrication causing wear on internal pump
parts .
Mount a low-pressure switch in front of the
pump and check its set point/ function . The
low- pressure switch ensures that the pump
does not start until the inlet pressure has
reached 1 bar .
2.3 Rotation speed (rpm)
2 .3 .1 If VFD-operated, check frequency .
2 .3 .2 Check that rotation speed of the electric
motor is as stated on name plate on
electric motor . Check that the motor rotor
winding is not damaged .
Speeds below min . limit (see User manual)
result in insufficient internal lubrication causing
wear on the internal pump parts .
2.
Reduced flow/reduced pressure
Summary of Contents for APP W HC Series
Page 32: ...Danfoss DCS im 10 2019 AI283147317727en 000601 32...
Page 42: ...Danfoss DCS im 2019 10 AN283148361728en 000402 42...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 47: ...47 180R9410 AQ282628894589en 000801 IOM APP W HC 15 30 Pumps 01 2022...
Page 52: ...Danfoss DCS im 2021 09 AX283334052821en 000301 52...
Page 60: ...Danfoss DCS im 2018 11 AX283149261730en 000301 60...
Page 61: ...Service guide Trouble shooting guide APP APP S and APP S 674 pumps ro solutions com...
Page 72: ...Danfoss DCS im 2017 04 521B1447 DKCFN PZ 003 A1 02 72...
Page 79: ......
Page 80: ...Danfoss DCS im 2022 01 180R9410 AQ2282628894589 en 000801 IOM APP W HC 15 30 Pumps 80...