Instruction | Recommended service intervals for APP W HC 15 - 30 pumps
50
180R9410 | AQ282628894589en-000801 | IOM APP W HC 15-30 Pumps | 01.2022
Pos.
Qty.
Description
Material
Service interval
1
1
Housing, main bearing
Duplex, PEEK
No need for service
11, 125,
1
Mounting flange/
end flange
Wetted part: Duplex
Dry part: AISI 316L
No wear part
121
1
Port flange
Duplex
No wear part
31
1
Swash plate
Super Duplex
32,000 hours
66
5/7/9
Piston
Super Duplex and PEEK
Recommended inspection
on a yearly basis and
evaluated acc . to app . 1
Replace after 24,000 hours
92
1
Valve plate
Super Duplex
24,000 hours
91
1
Port plate
Super Duplex, PEEK
24,000 hours
61
1
Cylinder barrel
Super Duplex
32,000 hours
65
1
Retainer plate
Super Duplex
32,000 hours
64
1
Retainer ball
Super Duplex
32,000 hours
71
1
Retainer guide
Super Duplex
32,000 hours
62
1/4
Spring
Duplex
40,000 hours
63
1
Spring guide
Duplex or PP
40,000 hours
142
1
Stop for shaft seal
PP
No wear part
124
1
Shaft seal
Hastelloy and NBR
24,000 hours
125
1
Cover/flange for shaft seal
Super Duplex
No wear part
93
5/7/9
Back-up ring
PTFE
24,000 hours
*
O-ring (overall)
NBR
24,000 hours
*
Screw (overall)
AISI 316
24,000 hours
*
Pin (overall)
AISI 316, Duplex or PEEK
No wear part
152
1
Valve cone (flushing valve)
Duplex or PEEK
48,000 hours
3
2
Bleeding screw
Duplex
No wear part
67
1
Key
AISI 316
40,000 hours
1.
General information
This guideline provides information on the
recommended service intervals . The recommen-
dation is based upon good engineering practice
and on experience gained from operation even
under extreme conditions .
The recommendation is for guidance only .
2.
Design/features
Danfoss APP W HC pumps* are designed for long
operation and low maintenance and life cycle
costs .
Provided that the pump has been running
according to the Danfoss specifications, Danfoss
guarantees one year service-free operation,
however, max . 18 months from date of
production . After one year of operation it is
recommended to inspect the pump and replace
worn parts, if any .
If the Danfoss recommendations concerning
system-design (see our data sheet) are not
followed, the service life of the pumps might be
affected .
The recommended service intervals on the differ-
ent parts in the pumps appear from the table
below:
1 .
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
2 .
Design/features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
3 .
Appendix 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Table of Contents
*
depends on pump size
Summary of Contents for APP W HC Series
Page 32: ...Danfoss DCS im 10 2019 AI283147317727en 000601 32...
Page 42: ...Danfoss DCS im 2019 10 AN283148361728en 000402 42...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com...
Page 47: ...47 180R9410 AQ282628894589en 000801 IOM APP W HC 15 30 Pumps 01 2022...
Page 52: ...Danfoss DCS im 2021 09 AX283334052821en 000301 52...
Page 60: ...Danfoss DCS im 2018 11 AX283149261730en 000301 60...
Page 61: ...Service guide Trouble shooting guide APP APP S and APP S 674 pumps ro solutions com...
Page 72: ...Danfoss DCS im 2017 04 521B1447 DKCFN PZ 003 A1 02 72...
Page 79: ......
Page 80: ...Danfoss DCS im 2022 01 180R9410 AQ2282628894589 en 000801 IOM APP W HC 15 30 Pumps 80...