10
180R9267 / IOM APP 1.5-3.5 Appendices - v04 / 11.2013
Data sheet
APP pumps - APP 1.5-3.5
8
521B0850 / DKCFN.PD.013.FA6.02 / 09.2012
10.2 Complete unit
Pump
A
(mm)
B
(mm)
C
(mm)
D
(mm)
E
(mm)
F
(mm)
G
(mm)
H
(mm)
IEC Electric motor
APP 1.5
250
260
100
160
140
325
120
166
3.0 kW, IEC 100L-2
APP 1.8
250
290
112
190
140
340
120
166
4.0 kW, IEC 112M-2
APP 2.2
300
338
132
216
140
403
144
166
5.5 kW, IEC 132S1-2
APP 2.5
300
338
132
216
178
403
144
166
7.5 kW, IEC 132S2-2
APP 3.0
350
422
160
254
210
505
188
166
11 kW, IEC 160M1-2
APP 3.5
350
422
160
254
210
505
188
166
11 kW, IEC 160M1-2
11. Installation
11.1 Mounting
The figure below illustrates how to mount the
pump and connect it to electric motor/combus-
tion engine.
A: Flexible coupling
B:
Bell housing
C:
Motor shaft
If alternative mounting is required, please
contact Danfoss Sales Organization for further
information.
To ensure easy mounting of the flexible coupling
without using tools, the tolerances must be
dimensioned accordingly.
Note: Any axial and/or radial loads on the shaft
must be avoided.
The pump should be connected to the rest of the
plant with flexible hoses.
A
C
B
Min. 5 mm