2.4  

General guidelines for calculation of 

pressure losses

In order to avoid the risk of cavitation, the inlet 

pressure at the pump must be min. 0.9 bar  

(13 psi) abs.

The inlet line connection must be properly 

tightened, as possible entrance of air will cause 

cavitation.

The suction conditions can be optimized 

according to below guidelines.

521B0747   DKCFN.PI.010.D3.ML

2)  In 90° bends 

2)  In 920° Winkeln

2)  Dans les coudes 90°

2)  En codos de 90°

2.4 General comments on

Filtration

A good fi ltration is vital to ensure a long and trouble free life of

the pump.

When selecting a fi lter or strainer, please note that fi lter materials

should be compatible with water, i.e. should neither corrode or dissolve.

Also be aware of the electrochemical series of the applied materials.

Main fi lter must have a fi neness of 10 µm abs.ß 

10

 >5000.

The pressure loss across the fi lter should be monitored.

Water tank

Must be made of corrosion-proof material such as stainless steel or

plastic and must be sealed to prevent entrance of impurities from

the environment.

Automatic pressure equalization between tank and surroundings

must be ensured.

Inlet from the water supply and inlet to the pump should be placed in 

opposite ends of the tank to calm and deaerate the water, and to ensure 

optimum opportunity for particles to settle.

2.4 Generelle Bemerkungen über

Filtrierung

Eine gute Filtrierung ist für eine lange Lebensdauer der Pumpe

unerläßlich.

Wenn Sie Filter oder Sieb wählen, beachten Sie bitte, daß das Filter-

material Wasserverträglich sein muß, d.h. es darf weder korrodieren

noch wasserlöslich sein. Beachte auch die elektrochemischen

Ausführungen der verwendeten Materialien.

Das Hauptfi lter muß eine Feinheit von 10 µm Abs. ß 

10

 >5000

haben.

Der Druckverlust über das Filter sollte überwacht werden.

Wassertank

Muß aus nichtrostendem Material wie rostfreiem Stahl oder Plastik

sein. Um das Eindringen von Schmutzpartikeln aus den Umgebungen

zu verhindern, muß der Behälter verschlossen sein.

Der Druckausgleich zwischen Tank und Umgebung muß gewährleistet

sein.

Wasserversorgungseinlaß und die Saugleitung der Pumpe sollten

möglichst weit auseinander angebracht werden um das Wasser in

einem Zustand zu stillen und dadurch die best möglichen Voraus-

setzungen für das Absetzen von Partikeln zu schaff en.

2.4 Généralités concernant

La fi ltration

Une bonne fi ltration est vitale pour garantir une longue durée de 

vie exempte de problème.

Lors de la sélection d’un fi ltre ou d’une crépine, il est primordial que les 

matériaux utilisés soient compatibles avec l’eau (pas de corrosion ou 

d’érosion).

Vérifi ez également les caractéristiques électrochimiques des matériaux.

Le fi ltre principal doit présenter une fi nesse de 10 µm abs. ß 

10

 >5000.

La perte de charge au travers du fi ltre doit être contrôlée.

Le réservoir d’eau

Doit être construit dans des matériaux à l’épreuve de la corrosion (acier 

inoxydable ou plastique) et étanche pour éviter l’intrusion d’impuretés 

en provenance de l’extérieur.

Une égalisation automatique de la pression entre le réservoir et 

l’environnement doit être assurée.

La conduite d’alimentation du réservoir et la conduite d’aspiration de 

la pompe seront placées chacune à une extrémité du réservoir afi n 

d’éviter les turbulences, de permettre une désaération du système et de 

permettre aux particules de se déposer au fonds du réservoir.

2.4.   Comentarios generales sobre:

La fi ltración

Una buena fi ltración de la bomba es vital para un funcionamiento 

sin problemas y una larga vida para la bomba.

Para seleccionar un fi ltro o rejilla, por favor tenga en cuenta que los 

materiales del fi ltro deben ser compatibles con el agua, por ejemplo 

no se deben corroer ni disolver. También hay que tener en cuenta los 

potenciales electroquímicos de los materiales empleados.

El fi ltro principal debe de tener un corte de 10 μm absolutas. β 

10

 /5000.

La pérdida de presión a través del fi ltro debe controlarse.

El tanque de agua

Tiene que estar compuesto de materiales que no se corroan, como el 

acero inoxidable o el plástico, y tendrá que sellarse para prevenir la 

entrada de impurezas del medio.

La presión entre el tanque y su medio debe regularse de manera 

automática.

La entrada de agua del suministro de agua y la entrada a la bomba de 

agua se deben colocar en extremos opuestos del tanque para calmar y 

desoxigenar el agua, y para asegurarse de que las partículas se asienten.

In 90° bends

2.5  General comments on

Filtration

A good filtration is vital to ensure a long and 

trouble free life of the pump.

When selecting a filter or strainer, please note 

that filter materials should be compatible with 

water, i.e. should neither corrode or dissolve. Also 

be aware of the electrochemical series of the 

applied materials. Main filter must have a 

fineness of 10 μm abs. ß 10 >5000. The pressure 

loss across the filter should be monitored.

Water tank

Must be made of corrosion-proof material such 

as stainless steel or plastic and must be sealed to 

prevent entrance of impurities from the environ-

ment.

Automatic pressure equalization between tank 

and surroundings must be ensured.

Inlet from the water supply and inlet to the 

pump should be placed in opposite ends of the 

tank to calm and deaerate the water, and to 

ensure optimum opportunity for particles to 

settle.

521B0747   DKCFN.PI.010.D3.ML

Re 2.3 Reversible pumps

If exposed to high pressure in the outlet while the electric motor is not 

energized, the pumps will start spinning backwards. This will not harm 

the pumps as long as the pressure in the inlet does not exceed the max. 

pressure of 5 bar.

If a non-return valve is mounted in the inlet line, a low-pressure relief 

valve will also be required.

Alternatively a high-pressure check valve could be mounted in the

pump discharge line to prevent the pump from reversing.

The dotted setup ensures that the inlet pressure does not exceed the 

5 bar abs., when a non-return valve is mounted in the inlet. 

Re 2.3 Umkehrpumpen

Wenn Umkehrpumpen hohem Druck in der Auslassleitung ausgesetzt 

werden – während der Elektromotor nicht eingeschaltet ist –  werden 

die Pumpen rückwärts larufen. 

Solange der Einlassdruck den max. Druck von 5 bar nicht übersteigt, 

werden die Pumpen vom Rückwärtslauf nicht beschädigt.  

Wenn ein Rückschlagventil in der Saugleitung montiert ist, ist ein Nieder

druckbegrenzungsventil auch erforderlich.

Als Alternative kann ein  Hochdruck-Rückschlagventil im Auslass der 

Pumpe montiert werden, um Rückwärtslauf zu verhindern. 

Der mit den punktierten Linien gezeigte Aufbau sichert, dass der Ein-

lassdruck die 5 bar abs nicht übersteigen  wird, wenn ein Rückschlag-

ventil im Einlass montiert ist. 

Re 2.3 Pompes réversibles

En cas de contre pression lors de l’arrêt du moteur électrique, la pompe 

commencera à tourner en sens inverse. Ceci n’endommagera pas la 

pompe pour autant que la pression à l’entrée de la pompe ne dépasse 

pas 5 bar.

Si un clapet anti-retour est monté dans la conduite d’aspiration de la 

pompe, une soupape de sécurité basse pression devra également être 

montée.

Solution alternative : le montage d’un clapet anti-retour dans la 

conduite haute pression (refoulement) évitera une rotation inverse de la 

pompe.

Les recommandations précitées garantissent que la pression à l’entrée 

de la pompe ne dépassera pas 5 bar abs. lorsqu’un clapet anti-retour est 

monté dans la conduite d’aspiration de la pompe. 

Re 2.3.    Bomba reversible

Si se expone la salida de la bomba a alta presión mientras que el motor 

no esté en marcha las bombas empezarán a girar al revés. Esto no daña 

las bombas a no ser que la presión de la entrada supere los 5 bares. Si se 

pone una válvula antiretorno en la entrada, también se debe colocar una 

válvula de seguridad- Otra alternativa es poner una válvula antiretorno 

a la salida de la bomba para impedir que se invierta. La línea discontinua 

del gráfi co asegura que la presión no excedera los 5 bares cuando se 

monte una válvula en la entrada de la bomba.

General guidelines for calculation of pressure losses

1)  In smooth pipes and hoses 

In order to avoid the risk of cavitation, the inlet pressure at the 

pump must be min. 0.9 bar (13 psi) abs.

The inlet line connection must be properly tightened, as possible

entrance of air will cause cavitation.

The suction conditions can be optimized according to below guidelines

on page 4.

Generelle Richtlinien für die Berechnung von Druckverlusten.

1)  In geraden Rohren und Schläuchen

Um die Gefahr der Kavitation zu vermeiden muß der Druck am

Pumpeneinlaß min. 0,9 bar abs. sein.

Die Montage der Einlaßleitung muß korrekt ausgeführt werden, da

ein evtl. Lufteintritt Kavitation verursachen wird.

Die Saugverhältnisse können gemäß Richtlinien auf Seite 4 optimiert

werden.

Recommandations générales pour le calcul des pertes de charge.

1)  Dans les tubes lisses et les fl exibles

Afi n d’éviter tout risque de cavitation, la pression dans la conduite 

d’aspiration de la pompe sera de min. 0.9 bar (13 psi) abs.

La conduite d’aspiration doit être étanche afi n d’éviter une possible 

entrée d’air qui causerait de la cavitation.

Des conditions d’aspiration optimales peuvent être obtenues en suivant 

les recommandations décrites page 4.

Instrucciones generales para calcular las pérdidas de presión

1)  En tuberías lisas y mangueras

Para evitar el riesgo de cavitación, la presión de entrada en la 

bomba debe ser como mínimo de 0,9 bar (13 psi) abs.

La línea de la conexión de la entrada debe estar sellada correctamente, 

ya que en caso de que entre aire se producirá cavitación. Las 

condiciones de succión pueden ser optimizadas siguiendo las 

instrucciones de la página 4.

In smooth pipes and hoses

Summary of Contents for APP 5.1

Page 1: ...ion and Maintenance Manual APP pumps APP 5 1 10 2 MAKING MODERN LIVING POSSIBLE Lenntech info lenntech com Tel 31 152 610 900 www lenntech com Fax 31 152 616 289 info lenntech com Tel 31 152 610 900 w...

Page 2: ...inspection transportation handling lifting and storage 9 4 1 Arrival inspection 9 4 2 Warning 9 4 3 General safety information 9 4 4 Transport and handling 9 4 5 Return to supplier 10 4 6 Storage 10 5...

Page 3: ...7 4 Disassembling and assembling the pump unit 15 7 5 Assembling the pump unit 16 7 6 Procedure for mounting pump back onto electric motor 16 7 7 Getting the pump unit back into operation 16 7 8 Stor...

Page 4: ...ps v01 01 2013 This manual is valid for APP pumps with the following code numbers serial numbers Validity APP 5 1 Code no 180B3005 Serial no 03 APP 6 5 Code no 180B3006 Serial no 03 APP 7 2 Code no 18...

Page 5: ...5 180R9263 IOM APP Pumps v01 01 2013 EU Declaration of Conform ity...

Page 6: ...ty regulations and laws It is the responsibility of the safety officer or the chief operator to assure compliance with all local regulations that are not taken into account in this manual Changing the...

Page 7: ...alves must be verified and free flow from safety valves must be ensured All pipe and hose connections must be stress free mounted securely fastened to the pumps and well supported Improper installatio...

Page 8: ...d replacement of the complete motor pump unit it is recommended having sufficient space around the unit For easy access to the unit at least 1 meter 40 inches available space should be kept free aroun...

Page 9: ...ved in lifting and transporting the equipment see Safety chapter 2 must be trained in handling and safety procedures when lifting heavy loads Many of the pumps and pump units weigh more than 20 kilos...

Page 10: ...hat the unit load is balanced before attempting to lift as the centre of the mass is different from pump to pump and pump unit to pump unit How to mount the pump and the electric motor correctly toget...

Page 11: ...or rust is not removed the pump and the valves can be damaged and in the worst case damaged beyond repair 5 3 Fluid temperature Before start up the fluid and pump housing temperature must be above the...

Page 12: ...pump in outlet CP13 Check piping for possible air gaps 5 7 Lifting and positioning Lift the pump unit onto base Remember vibration dampers if needed Fasten the motor to the base See also chapter 4 Arr...

Page 13: ...ling true the hole in the bell housing not available on all bell houses If the motor is turning the wrong direction switch two phases in the connection box of the motor or reprogram the direction in V...

Page 14: ...Very high temperatures can indicate one or more damaged parts inside the pump The pump then needs to be stopped immediately and inspected before running again Contact the maintenance depart ment G Dr...

Page 15: ...For instructions on lifting the complete pump unit see chapter 4 Arrival inspection transportation handling lifting and storage H For the small pumps unscrew the bolts holding the pump to the bell ho...

Page 16: ...m the coupling manufacturer Mount the flexible coupling and bell housing according to the Data sheet appendix 1 and APP pump instruction appendix 2 7 7 Getting the pump unit back into operation Find i...

Page 17: ...gh pressure can lead to eye or skin damage Leaking can result in flooding which again can cause a risk of slipping tripping or falling If water is dripping into the electric motor it can lead to elect...

Page 18: ...utor 6 8 Dimensions 8 11 Disassembling 15 16 E Electric motor 6 7 8 9 10 11 12 13 16 17 Electrical failure 17 Electrical hazard 6 Electrics 12 EU Declaration of Conformity 5 F Failure 8 17 Filter cond...

Page 19: ...Front page for Appendices APP 5 1 10 2 User manual Appendices for Installation Operation and Maintenance Manual APP pumps APP 5 1 10 2 MAKING MODERN LIVING POSSIBLE...

Page 20: ...1 2013 Table of Contents 1 Data sheet for APP 5 1 10 2 pumps 521B0851 3 2 APP pump instruction APP 5 1 10 2 180R9072 13 3 IOM Electric motors 180R9230 21 4 Recommended service intervals for APP pumps...

Page 21: ...1 Data sheet for APP 5 1 10 2 pumps 521B0851 ro solutions com Data sheet APP pumps APP 5 1 10 2 MAKING MODERN LIVING POSSIBLE...

Page 22: ...required The pumps are fixed displacement pumps in which the flow is proportional to the number of revolutions of the input shaft and the pump displacement regardless of any counter pressure 1 General...

Page 23: ...1 APP 6 5 APP 7 2 APP 8 2 APP 10 2 Geometric displace ment cm3 rpm 50 63 70 80 100 in3 rpm 3 05 3 84 4 27 4 88 6 10 Flow 1800 rpm 1 m3 h 5 0 6 4 7 2 8 2 10 2 gpm 22 0 28 2 31 7 36 1 44 9 Min pressure...

Page 24: ...PP 5 1 66 4 0 17 4 8 3kW 9 7 kW 11 1 kW 1460 475 2 APP 5 1 79 4 7 20 9 10 0 kW 11 7 kW 13 4 kW 1752 475 2 APP 6 5 83 5 0 22 0 10 5 kW 12 3 kW 14 0 kW 1460 475 2 APP 6 5 100 6 0 26 4 12 6 kW 14 7 kW 16...

Page 25: ...se will be reduced if speed is reduced and vice versa Use flexible hoses in order to minimize vibrations and noise Since the APP pump is typically mounted on a bell housing or frame the noise level ca...

Page 26: ...nlet water is filtered properly to minimize the wear of the pump The main filter must have a filtration efficiency of 99 98 at 10 m We recommend that you use precision depth filter cartridges rated 10...

Page 27: ...Outlet connection M42 x 1 5 x 13 mm 0 51 inch depth Pump mounting flange 125 A2 Pump A mm B mm C mm D mm E mm F mm IEC Electric motor APP 5 1 350 437 160 254 210 498 11 kW HUC2 160 M 4 APP 6 5 350 43...

Page 28: ...essure is always to be maintained at min 0 5 bar 7 3 psi and max 5 bar 72 5 psi 1 Place the filter 1 in the water supply line in front of the APP pump 2 Place a monitoring pressure switch 2 set at min...

Page 29: ...ately after startup regardless of any counter pressure M Brine Permeate APP Feed 1 2 3 5 4 5 7 6 Provided that the APP pump has been running according to the Danfoss specifications on pre filtration p...

Page 30: ...s reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in spe...

Page 31: ...2 APP pump instruction APP 5 1 10 2 180R9072 ro solutions com Instruction APP pump instruction APP 5 1 10 2 MAKING MODERN LIVING POSSIBLE...

Page 32: ...Problems with reversing pumps e design of the system must ensure that self emptying of the pump ing standstill is avoided e inlet pressure of the pump must never exceed the outlet pressure s may typic...

Page 33: ...ceed 5 bar abs 72 5 psi 2 3 Reversible pumps If exposed to high pressure in the outlet while the electric motor is not energized the pumps will start spinning backwards This will not harm the pumps as...

Page 34: ...ured Inlet from the water supply and inlet to the pump should be placed in opposite ends of the tank to calm and deaerate the water and to ensure optimum opportunity for particles to settle 521B0747 D...

Page 35: ...n 6 Servicio T cnico 1 Identi cation 1 Identi caci n 2 Conception du syst 2 1 Syst mes ouverts avec r servo 2 2 Syst mes ouverts avec alimen 2 3 Pompes r versibles La conception du syst me doit gar l...

Page 36: ...o de una v lvula reguladora de presi n o por medio de una v lvula bypass colocada en el lado de alta presi n La v lvula se debe colocar lo m s cerca posible a la bomba En la apertura de la v lvula no...

Page 37: ...g temperatures please contact the Danfoss Sales Organization 5 2 Pressure The inlet pressure must be min 0 9 bar 13 psi and max 4 bar 58 psi abs At lower pressures the pump will cavitate resulting in...

Page 38: ...signed so that lubrication follows from the water itself and there is thus no oil in the pump The pump requires no periodic replacements of seals and valve parts 6 2 Repair In case of irregular functi...

Page 39: ...3 IOM Electric motors 180R9230 Electric Motors Motor Manual hoyermotors com Manual 180R9230...

Page 40: ...l frequency and the doubled supply frequency Only mount or remove drive components pulley coupling etc using suitable tools never hit the drive components with a hammer as this will cause damage to th...

Page 41: ...Combustible dust areas will be found in agricultural areas and in industrial environments Only one electrical installation may be installed in one specified area zone Only certificated cable glands fo...

Page 42: ...ed supply frequency Only mount or remove drive components pulley coupling etc using suitable tools never hit the drive components with a hammer as this will cause damage to the bearing The motor are b...

Page 43: ...4 Recommended service intervals for APP pumps 180R9199 Instruction Recommended service intervals for APP pumps MAKING MODERN LIVING POSSIBLE...

Page 44: ...per Duplex No wear part 93 5 7 9 Back up ring Teflon 24 000 hours O ring overall NBR 24 000 hours Screw overall AISI 316 No wear part Pin overall AISI 316 Duplex or PEEK No wear part 152 1 Valve cone...

Page 45: ...ns must be replaced The pictures below is ment as a guideline for evaluating the wear of the sliding surface Cavitation of the piston shoes New inspection is required in 3 000 4 000 hours Cavitation o...

Page 46: ...material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being n...

Page 47: ...5 APP parts list 521B0941 Parts list APP Pumps APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 MAKING MODERN LIVING POSSIBLE APP 5 1 10 2 APPW 5 1 10 2 APP 5 1 10 2...

Page 48: ...tion x x x x x x x x x x x x x Note The parts listed are not sold separately only in various kits Exploded view see next page Parts list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 11 521B0941 DKCFN PC 073 A...

Page 49: ...list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 13 521B0941 DKCFN PC 073 A11 02 12 2012 12 Exploded view APP 5 1 10 2 APPW 5 1 10 2 Parts list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 13 521B0941 DKCFN PC 073 A...

Page 50: ...uper Duplex 218 8 Screw M8x20 AISI 316 x x x x x x x x 219 1 Screw AISI 316 x x x x x x Instruction x x x x x x x x x x x x x Parts list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 12 521B0941 DKCFN PC 073 A...

Page 51: ...list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 13 521B0941 DKCFN PC 073 A11 02 12 2012 12 Exploded view APP 5 1 10 2 APPW 5 1 10 2 Parts list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 13 521B0941 DKCFN PC 073 A...

Page 52: ...w M8x20 x x x Screw M8x70 x x Screw M8x140 x Lifting eye x Note The parts listed are not sold separately only in various kits Parts list APP 0 6 38 APM 0 8 2 9 APPW 5 1 10 2 24 521B0941 DKCFN PC 073 A...

Page 53: ...6 Trouble shooting guide Guideline Trouble shooting guide for APP pumps MAKING MODERN LIVING POSSIBLE...

Page 54: ...umps 2 Trouble shooting guide for APP pumps Table of Contents Trouble shooting fish bone chart 1 No flow no pressure 2 Reduced flow reduced pressure 3 High torque on electric motor 4 Noise from pump 5...

Page 55: ...in filtration 2 1 Wear in pump internal leakage 2 1 9 Type of fluid 2 1 11 High fluid temperature 4 1 Air in fluid 4 2 Bleeding conditions of pump 4 3 Min max nominal inlet pressure 4 4 Pump reversing...

Page 56: ...ct pump from electric motor and check that the motor is capable of running with no load If motor type relay or the electrical fuse is blown check that electric motor is sized correctly 1 4 No rotation...

Page 57: ...ide is polished See index 6 3 If the ring is missing the piston is very worn The filters can be bypassed even if they are correctly mounted Some filters can create channelling where particles can pass...

Page 58: ...eck that electric motor is correctly sized 3 2 2 Check internal parts see item 2 1 3 2 3 Systems with more than one electric motor installed Start motors simultaneously Pumps run in parallel with casc...

Page 59: ...flow item 1 2 Pump reversing WARNING The pump must not run without water for more than a few seconds If the pump takes in water from the high pressure outlet line it builds up pressure and will eventu...

Page 60: ...oo many bends may create too fast flow turbulence through the pipes and thus increase the noise level 5 3 Hose stiffness 5 3 1 Use amore flexible hose Danfoss A S can provide flexible hoses Please con...

Page 61: ...as scratches and or a polished surface Even small scratches will give a loss of flow Picture 3 A good way to identify a worn valve plate is to hold a straight knife edge over the valve plate When hold...

Page 62: ...trademarks of Danfoss A S All rights reserved Danfoss A S High Pressure Pumps DK 6430 Nordborg Denmark Picture 1 If the port plate has scratches level differences or both between the arrows the port...

Page 63: ...7 Right and wrong 180R9042 MAKING MODERN LIVING POSSIBLE 180R9042 Right and wrong Trouble shooting guide for water hydraulic systems...

Page 64: ...ter upstream of the final load may damage the pump Pump location 4 Pump always to be placed below water surface level Pump location above water surface level will cause damage Water supply 7 System to...

Page 65: ...f grease prevent seizing Too much grease may develop biofilm causing operational failures Water supply 13 Fill system with water before starting to ensure lubrication and cooling Starting without wate...

Page 66: ...e self bleeding 2 Start and bleed the system without pressure by opening the bypass valve 3 Add the cleaning agent to give 3 agent water solution 4 Run the system for 60 min and activate all component...

Page 67: ...or provide better cooling Is the control light for low pump suction pressure on The filter is clogging Is the power supply ok Are control lights on Is the filter clogged Is the filter control light on...

Page 68: ...Is the filter clogged Is the filter control light on Replace filter element Contact serviceman Stamp Fill water into the system Trace leakage if any A blown fuse or short circuit Check power supply an...

Page 69: ...User manual Appendices for IOM APP Pumps APP 5 1 10 2 51 180R9263 IOM APP 5 1 10 2 Appendices v02 01 2013...