Service guide
|
Disassembling and Assembling, APP 21-43
© Danfoss | DCS (im) | 2017.06
10 | 180R9121 | 521B1018 | DKCFN.PI.013.A6.02
1. Place the swash plate upside down.
Remove the 2 bolts holding the swash
plate. Remove the mounting flange from
the swash plate.
3. Change the O-ring on the mounting
flange.
2. Check that the O-ring and pin are in good
condition (Provided with sealing set).
4. Mount the swash plate on the 2 pins.
Carefully by hand tilt the unit to
horizontal position and mount the 2 bolts
which hold the swash plate. Tighten the
bolts with a torqueaccording to exploded
view. Finally check the surface on the
swash plate for any marks or foreign
particles.
5. Mount the assembled part on the pump.
4. Disassembling and
assembling of the
swash plate
WARNING:
Make sure that the surface on the swash
plate does not get any marks.