O-ring
Service guide | Disassembling and Assembling, APP 0.6-1.0
© Danfoss | DCS (im) | 2017.08
180R9092| DKCFN.PI.013.EC5.02 | 521B0739| 5
16. Hold the pump topgether and carefully
turn it over to rest on the housing. To
prevent seizing-up, lubricate the threads
on the 2 screws and screw them into the
port flange and the housing. Use Molykote
D paste from Dow Corning or Klüber UH1
84-201 from Klüber lubrication. Tighten
the 2 flange screws accordiing to exploded
view.
15. Position the housing on the port flange
and over the guide pin.
18. Replace the O-ring on the SAE flange.
17.Mount the new shaft seal following the
instructions on page
14. Position the new spring, new spring
guide, new retaining ball, new retainer
and new pistons.
13. Replace O-ring on the port flange and
position the new cylinder barrel on the
port plate.