background image

3

3

Installation Guide 

AMV 110 NL, AMV 120 NL

Heating Solutions 

VI.CV.C3.1E 

SMT/SI

ENGLISH

Safety Note 

Prior to assembly and commissioning to 

avoid injury of persons and damages of the 

devices, it is absolutely necessary to carefully 

read and observe these instructions.

Necessary assembly, start-up, and 

maintenance work must be performed 

only by qualified, trained and authorized 

personnel. 

Prior to assembly and maintenance work on 

the controller, the system must be:

-  depressurized, 
-  cooled down,
-  emptied and 
-  cleaned.

Please comply with the instructions of the 

system manufacturer or system operator.

Mounting 

The actuator should be mounted with the 

valve stem in either horizontal position or 

pointing upwards. The actuator is fixed to 

the valve body by means of a ribbed nut 

which requires no tools for mounting. The 

ribbed nut should be tightened by hand.

Wiring 

Do not touch anything on the PCB.

Installation 

1.  Check the valve’s neck. The actuator 

should be in stem up position (factory 

setting). Ensure that the actuator is 

mounted securely on the valve body. 

2.  Energize the actuator according to the 

wiring diagram. 

3  The direction of stem movement can be 

observed on the position indicator 

❸①

.

Manual override 

(for service purposes only)

Caution:

Do not manually operate the drive under 

power!

Procedure:

•  Remove the cover 

.

•  Press and hold the button 

 (on the 

bottom side of the actuator) during 

manual override 

.

•  Place cover back on the actuator 

.

•  Install actuator on valve 

.

Remark:
A click after energizing the actuator indicates 

that the gear wheel has jumped into normal 

position.

Don’t dismount the actuator from the valve 

when it is in a stem down position!

If dismounted in a stem down position, there is 

a high risk that the actuator gets stuck.

DANSK

Sikkerhedsbestemmelser 

Disse instruktioner skal læses omhyggeligt 

forud for montering og indkøring samt 

respekteres for at undgå skader på personer 

og udstyr.

Nødvendigt monterings-, opstarts- og 

vedligeholdelsesarbejde må kun udføres 

af faglært og autoriseret personale. 

Forud for monterings- og 

vedligeholdelsesarbejde på regulatoren skal 

systemet være:

-  trykløst
-  nedkølet
-  tømt
-  rengjort

Systemproducentens eller -operatørens 

instruktioner skal overholdes.

Montering 

Motoren skal monteres, så ventilspindelen 

enten er i vandret stilling eller peger opad. 

Motoren monteres på ventilhuset med en 

riflet møtrik, der kan monteres uden værktøj. 

Den riflede møtrik skal spændes med 

håndkraft.

Eltilslutning 

Rør ikke ved noget som helst på 

printkortet!

*  Grå (Grey) / Spindel ned (Stem down)

**  Sort (Black) / Fælles (Common)

*** Rød (Red) / Spindel op (Stem up)

Installation 

1.  Kontroller ventilens hals. Motoren skal stå 

i en position med spindelen trukket op 

(fabriksindstilling). Kontroller, at motoren 

er monteret solidt på ventilhuset.

 

Det er obligatorisk at sætte motorens 

spindel i øverste position, inden den 

installeres på AB-QM-ventilen (se 

tegningerne for manuel overstyring). 

2.  Tilslut motoren iht ledningsdiagrammet.

3.  Spindelens bevægelsesretning kan ses på 

positionsindikatoren 

❸①

.

Manuel overstyring 

(kun i forbindelse med service)

Forsigtig 

Drevet må ikke betjenes manuelt, når 

strømmen er tilsluttet!

Procedure:

•  Tag dækslet af. 

•  Tryk på knappen 

 (på undersiden af 

motoren), og hold den inde under den 

manuelle overstyring. 

•  Sæt dækslet på igen. 

•  Monter motoren på ventilen. 

Bemærk:
Hvis der høres et klik, efter at strømforsyningen 

er sluttet til motoren, betyder det, at tandhjulet 

er drejet i normal position.

Motoren må ikke afmonteres ventilen, når 

spindelen står i nederste position!
Hvis motoren afmonteres, når spindelen står 

i nederste position, er der stor risiko for, at 

motoren sidder fast.

Summary of Contents for AMV 110 NL

Page 1: ...s AMV 110 NL y AMV 120 NL www danfoss es P gina 4 FRAN AIS Moteurs pour contr le trois points AMV 110 NL AMV 120 NL www danfoss fr Page 5 POLSKI Si owniki sterowane sygna em 3 punktowym AMV 110 NL AMV...

Page 2: ...2 AMV 110 NL AMV 120 NL AB QM 1 st gen AMV 110 NL AMV 120 NL AB QM 2 nd gen Installation Guide AMV 110 NL AMV 120 NL SMT SI VI CV C3 1E Heating Solutions...

Page 3: ...there is a high risk that the actuator gets stuck DANSK Sikkerhedsbestemmelser Disse instruktioner skal l ses omhyggeligt forud for montering og indk ring samt respekteres for at undg skader p persone...

Page 4: ...ntage mit voll ausgefahrener Antriebsstange besteht die gro e Gefahr dass der Stellantrieb stecken bleibt Nota de seguridad A fin de evitar lesiones y da os a personas y dispositivos es absolutamente...

Page 5: ...n position basse En cas de d montage avec la tige en position basse le moteur a de grands risques de rester bloqu POLSKI Warunki bezpiecze stwa Aby nie dopu ci do obra e cia a oraz uszkodzenia urz dze...

Page 6: ...ventila ko je drog v iztegnjenem polo aju e demonta o opravite z drogom v iztegnjenem polo aju se lahko pogon zatakne SLOVENSKY Bezpe nostn pozn mka Aby ste predch dzali poraneniu a po kodeniu os b a...

Page 7: ...7 7 Installation Guide AMV 110 NL AMV 120 NL Heating Solutions VI CV C3 1E SMT SI DEUTSCH Grey Stem down Black Common Red Stem up 1 AB QM 2 3...

Page 8: ...Installation Guide AMV 110 NL AMV 120 NL 73697000 VI CV C3 1E Produced by Danfoss A S 02 2012...

Reviews: