Principle of operation

The AK-SM 800AL has been designed with store personnel in 
mind, providing an easy to use and consolidated touch screen 
alarm console for your Danfoss System Manager 800 application.  
The main purpose of the AK-SM 800AL is to provide clear notifi-
cation when an alarm occurs from any of the connected System 
Managers and offers the ability to acknowledge alarms, via an 
easy to use touch screen.  The AK-SM 800AL also provides addi-
tional alert functionality via the use of local siren and alarm relay, 
which can be used for added security and peace of mind.
If configured to do so, the AK-System Manager units in the store 
will route alarms to the AK-SM 800AL.  The alarm routing to the 
logger is in addition to any routing already configured in the AK-
System Manager(s).
• Each AK-SM 800 unit has alarm action options to route any / all 

alarms to the AK-SM 800AL

• Acknowledging an alarm at the AK-SM 800AL will also acknowl-

edge the alarm at the relevant System Manager

• Set as default ‘active’ but user configurable, the AK-SM 800AL will 

show red front LED and buzzer when active alarm received

• Network indicator shows status of host network.  Failures in host 

network will result in red indicator and visible screen saver icon

• Screen saver is activated after 5 minutes of no user input or im-

mediately after logging out.  The screen saver will show a 'live' 
alarm status icon if active or acknowledged alarms are present in 
the system, else the screen will go blank

• Two alarm status screens, showing ‘Current & Acknowledged’ and 

‘Cleared’

• New alarm type filter (default all selected), ‘Refrigeration’, ‘HVAC’, 

Lighting’, Other’

• Simple alarm info shown in alarm screen, additional information 

shown via   icon

• Each action taken by the authorized user is captured in the AK-

SM 800AL audit trail

• The AK-SM 800AL offers a ‘reminder alert’ (user configurable), to 

ensure alarms that are still active in the system for x minutes are 
re-triggered locally (buzzer will be re-triggered) 

Installation

The mounting location should be flat, dry and free of major vibra-
tions. The AK-SM 800AL should be mounted at eye level and with 
consideration to ensure easy touch screen operation.  Please refer 
to the included Instructions, provided in the product packaging 
for additional details on mounting and initial installation.
The AK-SM 800AL must be connected to a IP host network with 
at least one other AK-SM 800 unit (running minimum 08.06x 
software or above).   

Note

:  The AK-SM 800AL has a fixed host network address of 9, 

the position of the rotary host address switch is not used for the 
AK-SM 800AL.

Summary of Contents for AK-SM 800AL

Page 1: ...Alarm Logger AK SM 800AL User Guide ADAP KOOL Refrigeration Control System...

Page 2: ...of the System Manager host network utilizing IP Ethernet communications between all units Alarms raised at any System Manager 800 can be forward ed routed to the alarm logger for action and escalation...

Page 3: ...network Failures in host network will result in red indicator and visible screen saver icon Screen saver is activated after 5 minutes of no user input or im mediately after logging out The screen sav...

Page 4: ...can be assigned in the system The first user is by factory default the Supervisor level this user has access to all configuration screens in the system As part of the AK SM 800 AL setup process the co...

Page 5: ...ically set all detected host AK SM 800 units for alarm logger alarm action rout ing Manual adjustment of these alarm actions is possible per site specifications AK SM 800 host units For the AK SM 800A...

Page 6: ...f enabled Enable alarm logger reminder alerts Enabled Disabled A reminder alert will be triggered if there are any new or acknowledged alarms in the AK SM 800AL The time between alerts is configurable...

Page 7: ...in alarm icon new alarms text or the alarms menu icon all three navigation paths will result in the Current Alarms screen being displayed Simplified alarm details will be shown on this screen showing...

Page 8: ...the appropriate software to load During the software update a progress bar will be shown and typically the AK SM 800AL will reset Note Software must be located on the root directory of the USB Flash...

Page 9: ...a c 50 60 Hz Built in alarm relay Contact voltage Up to 240V Load AC 1 Ohmic Current rating 5 Amp AC 15 inductive Current rating 3 Amp LCD Active TFT colours thin film transistor SVGA 800 x 600 Size U...

Page 10: ...e right to alter its products without notice This also applies to products already on order provided that such alternations can be made without subsequential changes being necessary in specifications...

Reviews: