background image

Aeroquip by Danfoss FT1380P Crimp Machine Operator’s Manual

8 | Aeroquip by Danfoss FT1380P Crimp Machine Operator’s Manual | 2023.06.

AQ435955684211en-000101

Calibration

!

 

WARNING:

 Maintain clear distance from all moving parts.

The calibration procedure below will calibrate the Aeroquip ProCrimp 
FT1380P crimp machine to the original factory setting. New machines 
are calibrated at the factory and will be ready to use out of the crate. 
This procedure should be followed if the crimp machine has been 
disassembled or has had components replaced. The procedure requires 
the use of an FT1380-200-M240 die cage and a 1SB8 socket (or 1A -8 
fitting). 

1. 

   Loosen the clamp on the micrometer bracket assembly and posi-

tion the end of the bracket 0.250 inches from the top of the crimp 
ring. Tighten the clamp to hold the micrometer bracket assembly in 
place.

2. 

   Verify that the micrometer is positioned securely inside the bracket 

assembly. This can be done by adjusting the cap screw on top of 
the bracket assembly. (NOTE: DO NOT overtighten to assure free 
movement of the micrometer head.)

3.

    Insert an FT1380-200-M240 die cage.

4.

   Adjust the micrometer setting to 0.760.

5.

    Center a 1 SB8 socket or TTC -8 fitting (without a hose) in the die 

cage, holding the socket in place with a pencil or other suitable 
tool. Actuate the pump until the crimp ring stops advancing, indi-
cating a complete cycle. Relieve the pressure on the pump, and the 
crimp ring will retract.

NOTE:

 When using an air/oil pump, fully actuate the switch during 

the crimp cycle. Actuating the switch part way will cause a variation in 
crimp diameter.

6.

   Using a set of calipers, measure the crimp diameter. The preferred 

method is to use the average of the four pairs of indentations.

7. 

   The correct crimp diameter is 1 .000±0.003 inches. If the mea-

sured crimp diameter does not meet this specifi cation, refer 
to Table A for the new distance to set the micrometer bracket 
assembly from the top of the crimp ring (Bracket to Ring Gap) and 
repeat steps 1, 5 and 6.

NOTE:

 If your Crimp Diameter falls between the numbers shown 

in Table A, simply determine or interpolate the Bracket to Ring Gap, 
since the relationship between the numbers is linear.

Table A

Crimp 

Diameter

Bracket to  

Ring Gap

1.050 

.005 

1.040 

.029

1.030 

.053

1.020 

.077

1.010 

.101

1.000

.125

0.990 

.149 

0.980 

.173

0.970

.197

0.960

.221

0.950

.245

Summary of Contents for Aeroquip FT1380P

Page 1: ...Operator s Manual Aeroquip by Danfoss Procrimp FT1380P Crimp Machine...

Page 2: ...cifications 3 Accessories 3 Setup and Assembly lnstructions 4 Operating Instructions Loading and Unloading Die Cages 5 Establishing Crimp Setting 5 Crimping Procedures 6 Calibration Maintenance Mainte...

Page 3: ...ot rest your hand on the crimp ring Keep your hands clear of all moving parts Do not allow anyone other than the oper ator close to the equipment while it is in operation 4 MAINTAIN DIES WITH CARE Die...

Page 4: ...p Internal skive fittings Hose that requires a positive stop including the following Aeroquip hoses 2807 2808 FC186 FC465 FC469 and FC505 Accessories Die Holder Kit A plate and mounting hardware that...

Page 5: ...our 1 2 inch lag screws or other suitable fasteners 2 Install the die cage hanger bracket on the back of the crimper base optional 3 Place the pump on the bench to the right of the crimper and remove...

Page 6: ...may be inserted or removed in this position Establishing Crimp Setting The three digit micrometer display setting determines the crimp diameter for each combination of hose fitting and crimp cage The...

Page 7: ...crimped the crimp ring will stop moving indicating the crimp operation is complete Internally a hydraulic valve shifts to divert the fluid back to the reservoir Further pump ing will not result in add...

Page 8: ...head 3 Insert an FT1380 200 M240 die cage 4 Adjust the micrometer setting to 0 760 5 Center a 1 SB8 socket or TTC 8 fitting without a hose in the die cage holding the socket in place with a pencil or...

Page 9: ...ip part num ber FT1092 FT1092 is an 8 ounce container that will provide sufficient lubricant for about 5 000 crimps Periodically remove High Efficiency PTFE Grease Danfoss part num ber T 400 G residue...

Page 10: ...GGG0790000 Hose Assembly not included with FT1380P 1 3 Kit 1 14 2021 6 6S Adapter not included with FT1380P 1 3 Kit 1 15 FT1380P 3 12 Pressure Plata 1 16 1C0190BEEE0160A Hose Assemblv 1 Item Part Numb...

Page 11: ...1330 2 9 21 FT1330 2 9 2 Die Spring 8 or 16 2 FT1380 2 9 3 FT1380 2 9 2 Front Plate 1 3 FT1330 2 9 13 FT1330 2 9 3 Spring Plate 1 4 FT1330 2 9 55 FT1330 2 9 5 Button Head Cap Screw 4 5 FT1330 2 9 66 F...

Page 12: ...6 6 M180 0 751 6 M210 0 884 6 M180 0 772 8 M240 0 912 8 M240 0 792 8 M240 0 907 12 M320 0 949 10 M280 0 850 10 M240 0 652 16 M370 0 620 12 M320 0 880 12 M320 0 935 16 M370 0 521 16 M370 0 608 20 M465...

Page 13: ...ety of equipment and applications around the world We proudly engineer to support a sustainable future for tomorrow To learn more please visit http www danfoss com en about danfoss our businesses powe...

Reviews: