Aeroquip by Danfoss FT1380P Crimp Machine Operator’s Manual
11 | Aeroquip by Danfoss FT1380P Crimp Machine Operator’s Manual | 2023.06.
AQ435955684211en-000101
Die Cage Components
Hydraulic Schematic
Detail Number
FT1380-2-9 Bill of Material
FT1380-2-9A Bill of Material
Description
Qty Req’d
1
FT1330-2-9-21
FT1330-2-9-2
Die Spring
8 or 16*
2
FT1380-2-9-3
FT1380-2-9-2
Front Plate
1
3
FT1330-2-9-13
FT1330-2-9-3
Spring Plate
1
4
FT1330-2-9-55
FT1330-2-9-5
Button Head Cap Screw
4
5
FT1330-2-9-66
FT1330-2-6-6
Spacers
4
6
FT1380-2-9-1
FT1380-2-9-1
Back Plate
1
*The FT1380-200-NO. (FT1380-2-9) requires 16 springs and the FT1380-201-NO. (FT1380-2-9A) requires 8 springs.
Sequence
1. Pump on - Cylinder advances.
2. Valve energized - Cylinder holds
position.
3. Pump and Valve de-energized
-Cylinder retracts.