11
July 31, 2019
IQ-CONTROL BOX FRONT VIEW
IQ-CONTROL BOX TOP VIEW
Figure 3:
IQ-Control Box
Output LED Indicators And Output fuses
12. TOUCHPAD FILE UPLOAD ERROR CODES
#
Error Name
Error Description
LCD Display
1
FIELD_COUNT
TPP file fields counts is wrong, file content is wrong
Error 1
2
INVALID_VERSION
TPP file version is wrong
Error 2
3
WRONG_TOUCHPAD
TPP file is defined wrong TouchPad type
Invalid TP
4
UNEXPECTED_RECORD
TPP file unexpected record exist, file content is wrong
Error 4
5
LIGHTBAR_COMM
TouchPad has no communication with LightBar
L Comm Err
6
RELAY_COMM
TouchPad has no communication with Relay Board
R Box Err
7
FILE_ERR
TPP file read / write error
Error 7
8
USB_ERR
Detect USB thumb drive error
Init Failed!
Remove Drive
9
MEMORY_ERR
Read USB thumb error
Memory Fault
10
FILE_NOT_FOUND
There is no TPP file in USB thumb
No TP Files
11
RA_MESG_ERR
Road Alert Message Board communication error
Error 11
15
FILE_OK
TPP file upload successful. No error
Done!
CONNECTOR #11: DATA
Figure 2