9
July 31, 2019
9. F5M-IQ TEMPERATURE CALIBRATION (optional equipment)
The F5M-IQ system provides an optional connection for up to 3 temperature sensor modules.
To calibrate the temperature follow these steps:
10. F5M-IQ TOUCHPAD BACKLIGHT QUICK SETTING
The F5M-IQ system provides a 6 level quick adjustment for the touchpad backlight.
To make a quick adjustment of the touchpad backlight follow these steps:
Step 1:
Using a thermometer, record the temperature were the temperature sensor is installed.
Step 2:
Repeat
Step 2
to
Step 6
from previous section: “
8. F5M-IQ VOLTAGE CALIBRATION
” .
Step 3:
Enter “CALIBRATION TEMPSENSOR 1”.
Adjust the temperature on the display to match the temperature measured in
Step 1.
Use SW9 to increase and SW10 to decrease value.
Step 4:
Press SW8 to save.
If a second temperature sensor is present, repeat
Step 3
to calibrate
TempSensor 2
.
If not, the system will exit temperature calibration process.
Step 5:
Press SW8 to save.
If the third temperature sensor is present, repeat
Step 3
to calibrate
TempSensor 3
.
If not, the system will exit temperature calibration process.
Step 6:
Press SW8 to save and exit temperature calibration.
Step 1:
Press and hold down SW1.
Step 2:
After 3 seconds the backlight quick adjustment is enabled. Keep holding down SW1.
Step 3:
Every couple of seconds the touchpad will beep and change the backlight to the next intensity
level. Once the highest level is reached it will start a new cycle by selecting the lowest backlight
level.
Step 4:
Once the desired backlight level is selected, release SW1. The new backlight level is saved and
the touchpad will resume the normal operation.