background image

 

212-0019-IQ                                                                                                                                                                                                                 4  

ENFORCER

TM

  6201-IQ:

 

The unit consists of the siren chassis box, the switch controller and the harness (standard 18’ long). The long 
harness gives the flexibility in choosing the place where the siren will be installed.  

The siren can be mounted under the dash, on the transmission hump on the floor, or in the trunk. When in-
stalling  the  unit  on  the  transmission  hump,  BE  CAREFUL.  Using  long  screws  or  drilling  deep  can  cause 
damage to the transmission. This unit can also be mounted in a console using a face plate. 

The switch controller chassis is small and compact and can be easily mounted under the dash or other out of 
sight places. 

 

WIRING & ADJUSTMENTS

:

 

While wiring the siren, refer to the Wiring Diagram on page 5 for proper installation and operation of the sys-
tem. 

The harness has the switch controller and the plug factory installed, which will connect with the siren socket. 

If, by any reason, the plug is removed from the harness, to properly rewire the plug, strip away approximately 
1/4” of insulation off the wire.  Insert the wire in the proper hole and tighten the set screw.  Ensure that no 
strands of wire are sticking out of the hole, and that not too much insulation has been stripped away leaving 
bare wire exposed.  This can otherwise result in possible shorting of the system. 

DANGEROUS !

 

  Do  NOT  attempt to operate or test the system before ensuring a  SECURE  GROUND  AND 
  POWER  CONNECTION  USING  A  DEDICATED  SET  OF  WIRES  FROM  THE    
  BATTERY  TO  THE  SYSTEM. 

  

Manufacturer’s recommendations of wire size and tight connections will provide a longer    

  operating life for components. 
  Route wiring using grommets and sealant when passing through compartment walls. 
  Looms, grommets, cable ties and similar installation hardware should be used to anchor and  
  protect wiring and devices. 
  Particular attention should be paid to the location and method of electrical connection and   
  splices to protect these points from corrosion and loss of conductivity. 
  Ground termination should ONLY be made to substantial chassis components; preferably the  
  battery. 
  The user should install a circuit breaker in the supply line to protect against short circuits;  
  preferably one with a 20 Amp rating. 

WARNING

 

Summary of Contents for 6201-IQ

Page 1: ... INSTALLATION OPERATION MANUAL CONTENT PAGE UNPACKING 2 INTRODUCTION 2 STANDARD FEATURES 2 INSTALLATION MOUNTING 3 MOUNTING THE ENFORCERTM 6201 3 WIRING ADJUSTMENTS 4 MAINTENANCE 7 TROUBLE SHOOTING 7 SPECIFICATIONS 8 WARRANTY 9 PRODUCT RETURN POLICY 9 ...

Page 2: ...r such applications STANDARD FEATURES SIREN MODE There are two available siren tones WAIL and YELP The siren tones can be selected using the toggle switch from the remote controller switch UP for WAIL tone switch DOWN for YELP tone MANUAL MODE In the MANUAL mode the siren makes AIR HORN It is a momentary mode activated by holding down the AIR HORN switch on the siren s remote controller NOTE MANUA...

Page 3: ...rer s recommended guidelines It is the installer s responsibility to ensure that the unit mounting hardware and electrical wiring does NOT interfere with the air bags and SRS wiring and sensors INSTALLATION MOUNTING The ENFORCER 6201 IQ series sirens can be mounted in a variety of places They can be console mounted with 10 screws as shown in figure below While installing the unit refer to the Wiri...

Page 4: ...ately 1 4 of insulation off the wire Insert the wire in the proper hole and tighten the set screw Ensure that no strands of wire are sticking out of the hole and that not too much insulation has been stripped away leaving bare wire exposed This can otherwise result in possible shorting of the system DANGEROUS Do NOT attempt to operate or test the system before ensuring a SECURE GROUND AND POWER CO...

Page 5: ...212 0019 IQ 5 Figure 2 WIRING DIAGRAM MODEL ES6201 IQ ...

Page 6: ...WG RED wire from the harness PARK KILL To be connected to the park switch of the car system ground activated SPEAKER SPEAKER WAIL To be connected to the 22 AWG Green wire from the harness YELP To be connected to the 22AWG White wire from the harness AIRHORN To be connected to the 22 AWG BLACK wire from the harness RJ 45 COUPLER Factory programming MIC INPUT To connect the microphone or microphone ...

Page 7: ...problem persists please contact our service department PROBLEM POSSIBLE CAUSE PROBABLE SOLUTION No output Siren is not connected to power source The switch box harness has loose wires Electronic fuse 20A is blown Ensure secure connection of the 9pin con nector Ensure secure connection of the harness at both ends Replace fuse with same rating if blown fuse location internal Functions work but there...

Page 8: ...nput OFF time out ØmA after time out Siren Operating Current 10 Amps Frequency Range 700 to 1640 Hz nominal Cycle Rate Wail 20 cycles min Yelp 200 cycles min Nominal Voltage Output 52V p p 11Ω load Audio Frequency Response 100 4000 Hz 3dB Audio Distortion 10 or less Audio Power 32 watt Amplifier Output Impedance 11 Ohms MODEL 6201 IQ SIREN BOX Net Weight 4 76lb Height 2 0 Width 8 75 Depth 6 75 CON...

Page 9: ...l or installation Lamps flash tubes batteries or other items considered consumables are not covered under warran ty Any attempt to repair a unit under warranty by anyone else other than a technician authorized by D R Electronics without the express or written consent of the manufacturer D R will void the warranty WARRANTY D R ELECTRONICS Co LTD CANADA USA 8820 George Bolton Pkwy 2321 Kenmore Avenu...

Reviews: