27
063
Function mapping F1(f+r)
See supplement 1
If par063 is written, par075 will be
set to the same value
0 – 255
4
064
Function mapping F2(f+r)
See supplement 1
If par064 is written, par085 will be
set to the same value
0 – 255
8
065
Function mapping F3
See supplement 1
0 – 255
16
066
Function mapping F4
See supplement 1
0 – 255
128
067
Function mapping F5
See supplement 1
0 – 255
32
068
Function mapping F6
See supplement 1
0 – 255
0
069
Function mapping F7
See supplement 1
0 – 255
0
070
Function mapping F8
See supplement 1
0 – 255
64
071
Function mapping F9
See supplement 1
0 – 255
0
072
Function mapping F10
See supplement 1
0 – 255
0
073
Function mapping F11
See supplement 1
0 – 255
0
074
Function mapping F12
See supplement 1
0 – 255
0
075
Function mapping F1(r)
See supplement 1
In case par075 should have
another value as par063, you
have to set par063 first and then
par075
0 – 255
4
076
Timer for clear AUX1
Each 100 ms, 0 = deactivated
0 – 250
0
077
Timer for clear AUX2
Each 100 ms, 0 = deactivated
0 – 250
0
078
Timer for clear AUX3
Each 100 ms, 0 = deactivated
0 – 250
0
079
Timer for clear AUX4
Each 100 ms, 0 = deactivated
0 – 250
0
081
Dimming light "normal"
0 = off … 31 = full brightness
0 – 31
31
082
Dimming light "alternative"
0 = off … 31 = full brightness
0 – 31
15