25
019
Shunting gear deceleration
See par011
0 – 255
1
021
Signal-stopping section
1 or 2
0, 1
0
022
Consist mode F1 – F8
Reserved
023
Consist mode FL, F9 – F12
Reserved
024
Preclusion for LV
Bit 0 = F1 to bit 7 = F8
0 – 255
0
025
Preclusion for LR
See par024
0 – 255
0
026
Preclusion for AUX1
See par024
0 – 255
0
027
Preclusion for AUX2
See par024
0 – 255
0
028
Analog mode F1 – F8
Bit
Function
Value
0
F1
1
1
F2
2
2
F3
4
3
F4
8
4
F5
16
5
F6
32
6
F7
64
7
F8
128
0 – 255
1
029
Analog mode FL, F9 – F12
Bit
Function
Value
0
FL (f)
1
1
FL (r)
2
2
F9
4
3
F10
8
4
F11
16
5
F12
32
0 – 63
3
031
Interchange of track connections
0 = normal, 1 = inversed
0, 1
0
032
Interchange of motor connections
0 = normal, 1 = inversed
0, 1
0
033
Interchange of light connections
0 = normal, 1 = inversed
0, 1
0
Summary of Contents for DHP160