35
44
Function mapping F10
(See supplement 1)
0
– 255
(0)
45
Function mapping F11
(See supplement 1)
0
– 255
(0)
46
Function mapping F12
(See supplement 1)
0
– 255
(0)
47
Function mapping F1(r)
(See supplement 1)
In case CV47 should have a different value than CV35, you have to set CV35 first
and then CV47
0
– 255
(4)
48
Speed step characteristic
(See supplement 2)
0 = linear ... 7 = strongly curved
0
– 7
(5)
49
Impulse width
(Not relevant to FH05B/FH18A/FH22A)
0 = 1 ms, 1 = 2 ms, 2 = 4 ms, 3 = 8 ms
0
– 3
(1)
50
Control variant
(No relevant to FH05B/ FH18A/FH22A)
0 = defined by CV56 - CV59, 1 = hard, 2 = soft, 3 = very soft
0
– 3
(2)
51
Interchange of connections
Bit Function
Value
0 Motor connections
1 (Not relevant to FH05B/ FH18A/FH22A)
1 Light connections
2
2 Track connections
4
0
– 7
(0)
52
Dimming light LV/LR
0 = dark
… 31 = full brightness
0
– 31
(31)
53
Dimming dimmed headlight
(See CV156)
0 = dark
… 31 = full brightness
0
– 31
(15)
54
Dimming AUX1
0 = dark
… 31 = full brightness
0
– 31
(31)
55
Dimming AUX2
0 = dark
… 31 = full brightness
0
– 31
(31)
56
Motor control proportional
(Not relevant to FH05B/FH18A/FH22A)
Only if CV50 = 0, see: www.doehler-haass.de/"Häufige Fragen" (Only in German)
0
– 7
(3)
57
Motor control integral
(As CV56)
0
– 3
(3)
58
Motor control measurement period
(As CV56)
0
– 3
(1)
59
Motor control impulse width
(As CV56)
0
– 7
(3)
Summary of Contents for DH05C