Mixed KSL array configuration
9.1 Remarks
NOTICE!
▪ For a mixed setup, the Z5722 KSL Flying frame together with
the Z5723 KSL Load beam must always be used as a
suspension device. The Z5747 KSL-SUB Adapter frame is
required in addition.
▪ Observe the maximum total system weight of 1500 kg
(3307 lb) – SWL including all rigging components.
▪ The SUB cabinets must always be interconnected with
0° splay.
Chapter3.15.1 "Front link mechanism"
Fig.2: "SUB to SUB 0° splay" on
9.1.1 Rigging modes
In connection with the adapter frame, the TOP cabinets underneath
the SUB cabinets can also be set up in either tension or
compression mode. However, for the compression mode setup, the
same safety rules apply.
WARNING!
Potential risk of personal injury and/or
damage to material.
When using a motor hoist instead of the lever hoist, observe the
following:
▪ The maximum permitted compression force is 1000 kg
(1.0 t/10 kN).
The hoist overload clutch must be correspondingly adjusted.
▪ The motor hoist must be equipped with two independent brakes
(according to the German
D8 Plus standard).
▪ Observe your local legal requirements and Rules for the
Prevention of Accidents (RPA).
9.2 Order of assembly
The assembly of a mixed array configuration is divided into the
following three main procedures:
1. Suspending the desired number of SUB cabinets.
2. Attaching the adapter frame.
3. Attaching the TOP cabinets.
9.2.1 Suspending the desired number of SUB cabinets
The suspension and assembly of the SUB cabinets is similar to the
suspension and assembly of a pure SUB column, as described in
Chapter 8 "SUB columns" on page 58.
9 Mixed KSL array configuration
d&b SL-Series Rigging manual 1.10 en
63