4.4. Controls and indicators
4.4.1. Mains power switch
The on/off rocker switch
[5] is located on the rear panel.
OFF
Mains isolation is not provided. The mains power supply is
switched off but remains connected to the mains.
ON
The mains power supply is switched on and the device is
ready for operation.
4.4.2. POWER button and indicator
Switching on (boot up)
Þ
Provided the mains power switch
[5] at the rear is switched
on, pushing the POWER button
[6] will boot up the device.
Þ
The integrated LED indicator
[7] illuminates green.
Switching off (shut down)
Þ
To switch off (shut down) the device, briefly press the POWER
button.
Þ
After approx. 5 seconds (shut down), the device will be
switched off automatically.
Behavior after AC power interruption
If the AC power is interrupted, the device will remember its last
power state and restore it when the AC power is re-established.
This leads to the following behavior:
AC power interrupted
while device is:
Behavior after re-
establishing AC power:
On
Device powers up immediately:
Þ
Previous 'ON' state restored.
Þ
Device keeps 'ON' state.
Off
Device powers up immediately:
Þ
Previous 'OFF' state
restored.
Þ
Device shuts down.