background image

Operating Instructions

AIR FILTER

8

Your dehumidifer features a removable Air Filter,  located at the front of
the unit (behind the air intake grill) directly above the water tank
compartment.

The air filter plays an important role in helping to reduce (minimize)
dust/dirt particles from the surrounding environment. A blocked/clogged air
filter reduces air intake, impacting negatively on operating efficiency. 

To maintain maximum operating efficiency:

 The filter must be checked and cleaned regularly (

every 2 weeks

)

 More frequent cleaning may be required depending upon indoor air

quality.

IMPORTANT:

Never operate the unit without the air filter in place. 

AIR FILTER REMOVAL:
1)

Grasp the filter handle, and pull the filter out. The filter will slide out 

easily 

(see Fig. 2)

2) 

Clean the filter thoroughly using a vacuum cleaner or wash using 

lukewarm water and mild detergent. Dry thoroughly before re-installing.

3) 

To re-install the air filter, slide the filter back inside the tracks and push

inward.

Fig. 2

DIRECT DRAIN
FEATURE

This dehumidifier is inclusive of a direct drain feature, located at the right side
of the cabinet. 

NOTE:

The drain hose is not included with the unit. The

direct drain feature is intended for use in basements inclusive of a floor
drain only.

NOTE: 

Do not attempt to operate the direct drain feature using

Water can be automatically emptied into a floor drain by attaching the unit
with a water hose (24mm diameter not included)

 Remove the water bucket from the unit and set aside.

 Lift up the side flap located on the right side of the unit (looking at the

front). 

(Fig.3)

 Insert the female threaded end of the hose through the opening. 

(Fig.4a)

 Screw the garden hose onto the threaded portion of the tray underneath

the bucket opening. 

(Fig.4b)

 Make sure the hose is secure so there are no leaks.

 Direct the hose toward the drain, making sure that there are no kinks

that will stop the water flowing.

 Place the end of the hose ino the drain.

 Place the bucket back in the unit and make sure its positioned correctly.

(Fig.4c)

 Select the desired humidity setting and fan speed on the unit for

continuous draining to start.

Fig. 3

Fig.4a

Fig.4b

Fig.4c

Summary of Contents for DDR6511R1

Page 1: ...ed Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 Model Mod le Modelo Owner s Use and Care Guide Guide d utilisation et d entretien PORTABLE DEHUMIDIFIER D SHUMIDIFICATEUR PORTATIF V...

Page 2: ...nitiale de ce produit D SHUMIDIFICATEUR PORTATIF Guide d utilisation et d entretien Bienvenue Consignes de S curit Importantes Installation Caract ristiques Consignes d utilisation Soins et Entretien...

Page 3: ...nal aspects of this appliance For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on...

Page 4: ...alternating current circuit protected by a 15 ampere fuse equivalent fuse or circuit breaker The three prong grounding plug on the power cord should be plugged directly into a polarized three slot ef...

Page 5: ...d room ambient operating temperatures should be between 5 C 41 F 35 C 95 F It is important to remember the efficiency of a dehumidifier will be effected influenced by the rate at which new humid air m...

Page 6: ...rmal fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal 2 3 buttons Humidity Set Contr...

Page 7: ...rounding environment the dehumidifier may not start automatically when the on off button is pressed see dehumidifier operating instructions for details In the event of a power failure the unit will d...

Page 8: ...re to increase slightly This process also contributes to lowering the relative humidity of the surrounding air DEHUMIDIFYING MODE INSTRUCTIONS When the unit is first connected to the electrical outlet...

Page 9: ...and push inward Fig 2 DIRECT DRAIN FEATURE This dehumidifier is inclusive of a direct drain feature located at the right side of the cabinet NOTE The drain hose is not included with the unit The direc...

Page 10: ...U P D O WN H EA T FA N TIM ER CAUTION The unit will not operate if curtains doors or other materials block the signals from the remote controller to the unit Prevent any liquid from falling into the r...

Page 11: ...to select the continuous dehumidifying mode or dehumidifying mode only DEHUMIDIFYING FUNCTION Ensure the unit is plugged in and power is available Continuously Dehumidifying operation 1 Press the ON...

Page 12: ...to start time as in step 2 above In the 5 seconds after setting auto start time press the TIMER button again the Auto Stop program is initiated Set the auto stop time as in step 2 above 5 Turning the...

Page 13: ...batteries should be removed Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries This Class B digital apparatus complies with canadian I...

Page 14: ...washing detergent lukewarm water and a soft cloth to wipe the exterior surface of the unit and dry thoroughly Troubleshooting Occasionally a problem may arise that is minor in nature and a service ca...

Page 15: ...authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legisla...

Page 16: ...s sugg rons de joindre une copie de votre re u de caisse et ou facture d achat cette page et d inscrire les renseignements suivants qui sont trouv s sur la plaque d identification du fabricant Celle c...

Page 17: ...rise de courant polaris e de m me configuration et reli e la terre con u pour les circuits 110 120 V CA POUR VOTRE S CURIT Pour minimiser tout risque d incendie ou d explosion ne jamais remiser d esse...

Page 18: ...e entre 5 C 41 F 35 C 95 F Il est important de noter que l efficacit d un d shumidificateur sera influenc e par la taux de r introduction d air humide dans la pi ce Pour obtenir la meilleure efficacit...

Page 19: ...lev e High R glez le ventilateur High lev pour limin er le maximum d humidit Lorsque l humidit est r duite et un fonctionnement silencieux est pr f r r glez le ventilateur Normal 2 3 BOUTONS Touches...

Page 20: ...interruption de l alimentation le circuit de commande lectronique adopte automatiquement par d faut la configuration de r glage d finie l usine R glage delon l hygrom trie ambiante 60 Vitesse ventilat...

Page 21: ...automatiquement avec la configu ration de r glage adopt e par d faut ceci indique que le taux d hy grom trie de l environment est inf rieur 60 Par cons quent il sera alors n cessaire de s lectionner s...

Page 22: ...siphon de sol REMARQUE Ne tentez pas d utiliser la fonction de drainage direct avec le r ceptacle eau L eau peut se vider automatiquement dans un siphon de sol lorsque l on attache un tuyau l appareil...

Page 23: ...MISE EN GARDE L appareil ne fonctionne pas si le signal envoy par la t l commande l unit int rieure est bloqu par des rideaux des portes ou d autres mat riaux Ne laissez pas de liquides tomber sur la...

Page 24: ...mode de d shumidification con tinue ou le mode d shu midification seulement FONCTION DE D SHUMIDIFICATION Assurez vous que l appareil est branch et sous ten sion D shumidification continue 1 Appuyez...

Page 25: ...ue Suivez la proc dure d crite l tape 2 pour r gler le d lai de mise en marche automatique Dans les 5 secondes qui suivent le r glage du d lai de mise en marche automa tique appuyez sur le bouton TIME...

Page 26: ...terait la capacit de programmation de l unit principale Prot ger la t l commande contre les temp ratures lev es et viter l exposition la radiation Prot ger le r cepteur du panneau de contr le contre l...

Page 27: ...eau ti de un d tergent pour lave vaisselle et un chiffon doux pour essuyer complitement les surfaces externes de l appareil D pannage De temps en temps un probl me peut se poser qui est mineur et une...

Page 28: ...repr sentations en vertu de toute loi r gissant la vente de produits ou de toute autre l gislation ou r glement semblables En vertu de la pr sente Danby ne peut tre tenue responsable en cas de blessu...

Page 29: ...TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description D SHUMIDIFICATEUR PORTATIF Le num ro de mod...

Reviews: