background image

7

Operating Instructions

WATER TANK
OPERATION

IMPORTANT

Never tamper with or attempt to defeat the water level (safety) float
switch system. Proper installation of the water tank is crucial to
maintaining reliable dehumidifier operation.

The water tank holds accumulated condensed water and by means of a
safety switch, controls both the water level and operation of the dehumidi-
fication process- i.e. When the water tank is full and/or accidentally 
displaced inside the cabinet, the float switch actuator (inside the tank)
breaks contact with the safety switch. This condition results in the immedi-
ate shut down of the compressor and fan motor system, preventing 
moisture from being condensed.

DEHUMIDIFYING

DEHUMIDIFYING

is a means of removing moisture from the air. A dehu-

midifier will help to protect your home and valued possessions from dam-
age (swelling) caused by moisture in the air. Essentially a dehumidifier
removes moisture from air as moist air passes over a dehumidifying (evap-
orator) coil. Moisture is condensed on the evaporator coil, drained, and
collected inside an internal (removable) water tank located at the front of
the unit. The exhausted air being returned into the room environment is
elevated several degrees causing the surrounding air temperature to
increase (slightly). This process also contributes to lowering the relative 
humidity of the surrounding air. 

DEHUMIDIFYING MODE
INSTRUCTIONS

When the unit is first connected to the electrical outlet, the (green) power
light will be flashing until the “on/off” button is pressed. 

When the “on/off” button is activated (pressed), the power light turns to a
state “on” condition and the dehumidifier automatically defaults to:

Display: Current Ambient Room Humidity (RH%)
Humidity Setting:60% RH
Fan Speed: High

IMPORTANT NOTE:

Depending on humidity conditions of the surrounding

environment, the  dehumidifier may not start automatically under the
default setting (this is an indication that the humidity level of the surround-
ing environment is lower than the “default” setting of 60% RH). Therefore,
it may be necessary to scroll through each of the different dehumidifier
settings 35% - 8 % until the “humidstat” (sensor) recognizes conditions
that will allow the unit to operate.

DEHUMIDIFYING MODE SELECTION:
1)

To turn the unit on press the ON/OFF button.

2a)

Press the humidity “UP” or “DOWN” button to select a desired RH

operating value (35% -85%) 

OR

2b)

Press the CONTINUOUS button. When CONTINUOUS mode is

selected, the humidistat (sensor) will be by-passed and the
compressor will operate non-stop regardless of humidity conditions. 

FAN SPEED SELECTION: 
3) 

Select a fan speed on the keypad. The speed you select is identified by

the (illuminated) indicator light located directly above the selection
made.

5

Summary of Contents for DDR6511R1

Page 1: ...ed Ontario Canada N1H 6Z9 Danby Products Inc Findlay Ohio USA 45840 Model Mod le Modelo Owner s Use and Care Guide Guide d utilisation et d entretien PORTABLE DEHUMIDIFIER D SHUMIDIFICATEUR PORTATIF V...

Page 2: ...nitiale de ce produit D SHUMIDIFICATEUR PORTATIF Guide d utilisation et d entretien Bienvenue Consignes de S curit Importantes Installation Caract ristiques Consignes d utilisation Soins et Entretien...

Page 3: ...nal aspects of this appliance For easy reference may we suggest you attach a copy of your sales slip receipt to this page along with the following information located on the manufacturers nameplate on...

Page 4: ...alternating current circuit protected by a 15 ampere fuse equivalent fuse or circuit breaker The three prong grounding plug on the power cord should be plugged directly into a polarized three slot ef...

Page 5: ...d room ambient operating temperatures should be between 5 C 41 F 35 C 95 F It is important to remember the efficiency of a dehumidifier will be effected influenced by the rate at which new humid air m...

Page 6: ...rmal fan speed Set the fan control to High for maximum moisture removal When the humidity has been reduced and quiet operation is preferred set the fan control to Normal 2 3 buttons Humidity Set Contr...

Page 7: ...rounding environment the dehumidifier may not start automatically when the on off button is pressed see dehumidifier operating instructions for details In the event of a power failure the unit will d...

Page 8: ...re to increase slightly This process also contributes to lowering the relative humidity of the surrounding air DEHUMIDIFYING MODE INSTRUCTIONS When the unit is first connected to the electrical outlet...

Page 9: ...and push inward Fig 2 DIRECT DRAIN FEATURE This dehumidifier is inclusive of a direct drain feature located at the right side of the cabinet NOTE The drain hose is not included with the unit The direc...

Page 10: ...U P D O WN H EA T FA N TIM ER CAUTION The unit will not operate if curtains doors or other materials block the signals from the remote controller to the unit Prevent any liquid from falling into the r...

Page 11: ...to select the continuous dehumidifying mode or dehumidifying mode only DEHUMIDIFYING FUNCTION Ensure the unit is plugged in and power is available Continuously Dehumidifying operation 1 Press the ON...

Page 12: ...to start time as in step 2 above In the 5 seconds after setting auto start time press the TIMER button again the Auto Stop program is initiated Set the auto stop time as in step 2 above 5 Turning the...

Page 13: ...batteries should be removed Do not mix old and new batteries Do not mix alkaline standard carbon zinc or rechargeable ni cad ni mh etc batteries This Class B digital apparatus complies with canadian I...

Page 14: ...washing detergent lukewarm water and a soft cloth to wipe the exterior surface of the unit and dry thoroughly Troubleshooting Occasionally a problem may arise that is minor in nature and a service ca...

Page 15: ...authorized distributors and all other warranties conditions representations or guarantees including any warranties conditions representations or guarantees under any Sale of Goods Act or like legisla...

Page 16: ...s sugg rons de joindre une copie de votre re u de caisse et ou facture d achat cette page et d inscrire les renseignements suivants qui sont trouv s sur la plaque d identification du fabricant Celle c...

Page 17: ...rise de courant polaris e de m me configuration et reli e la terre con u pour les circuits 110 120 V CA POUR VOTRE S CURIT Pour minimiser tout risque d incendie ou d explosion ne jamais remiser d esse...

Page 18: ...e entre 5 C 41 F 35 C 95 F Il est important de noter que l efficacit d un d shumidificateur sera influenc e par la taux de r introduction d air humide dans la pi ce Pour obtenir la meilleure efficacit...

Page 19: ...lev e High R glez le ventilateur High lev pour limin er le maximum d humidit Lorsque l humidit est r duite et un fonctionnement silencieux est pr f r r glez le ventilateur Normal 2 3 BOUTONS Touches...

Page 20: ...interruption de l alimentation le circuit de commande lectronique adopte automatiquement par d faut la configuration de r glage d finie l usine R glage delon l hygrom trie ambiante 60 Vitesse ventilat...

Page 21: ...automatiquement avec la configu ration de r glage adopt e par d faut ceci indique que le taux d hy grom trie de l environment est inf rieur 60 Par cons quent il sera alors n cessaire de s lectionner s...

Page 22: ...siphon de sol REMARQUE Ne tentez pas d utiliser la fonction de drainage direct avec le r ceptacle eau L eau peut se vider automatiquement dans un siphon de sol lorsque l on attache un tuyau l appareil...

Page 23: ...MISE EN GARDE L appareil ne fonctionne pas si le signal envoy par la t l commande l unit int rieure est bloqu par des rideaux des portes ou d autres mat riaux Ne laissez pas de liquides tomber sur la...

Page 24: ...mode de d shumidification con tinue ou le mode d shu midification seulement FONCTION DE D SHUMIDIFICATION Assurez vous que l appareil est branch et sous ten sion D shumidification continue 1 Appuyez...

Page 25: ...ue Suivez la proc dure d crite l tape 2 pour r gler le d lai de mise en marche automatique Dans les 5 secondes qui suivent le r glage du d lai de mise en marche automa tique appuyez sur le bouton TIME...

Page 26: ...terait la capacit de programmation de l unit principale Prot ger la t l commande contre les temp ratures lev es et viter l exposition la radiation Prot ger le r cepteur du panneau de contr le contre l...

Page 27: ...eau ti de un d tergent pour lave vaisselle et un chiffon doux pour essuyer complitement les surfaces externes de l appareil D pannage De temps en temps un probl me peut se poser qui est mineur et une...

Page 28: ...repr sentations en vertu de toute loi r gissant la vente de produits ou de toute autre l gislation ou r glement semblables En vertu de la pr sente Danby ne peut tre tenue responsable en cas de blessu...

Page 29: ...TOLL FREE NUMBER When requesting service or ordering parts always provide the following information Product Type Model Number Part Number Part Description D SHUMIDIFICATEUR PORTATIF Le num ro de mod...

Reviews: