INSTALLATION

LOCATION

A)

This room air conditioner is designed to fit 

easily into a single or double hung window.

However, since window designs vary, it may be

necessary to make some modifications for safe,

proper installation.

B)

Make sure window and frame are structurally

sound and free from dry and rotted wood.

C)

For maximum efficiency, install the air 

conditioner on a side of the house or building

which favours more shade than sunlight. If the unit

is in direct sunlight, it is advisable to provide an

awning over the unit. 

D)

Provide sufficient clearance around the cabinet

to allow for ample air circulation through the unit

(See Fig. 2). The rear of the unit should be 

outdoors and not in a garage nor inside a building.

Keep unit as far away as possible from 

obstacles/obstructions and at least 30” above

the floor or ground. Curtains and other objects

within a room should be prevented from 

blocking the air flow. 

E)

Be certain the proper electrical outlet is 

within reach of the installation. Use only a 

single outlet circuit rated at 15 amps. All wiring

should be in accordance with local and 

national electrical codes.

TOOLS NEEDED FOR INSTALLATION:

Screw Drivers:  

Both Phillips and flat head

Power Drill:  

1/8 inch diameter drill bit

Pencil

Scissors

Measuring Tape

Carpenters Level

ELECTRIC SHOCK HAZARD:

To avoid the possibility of personal injury, disconnect power to

the unit before installing or servicing. 

3/4” screws (9)

3/8” screws (4)

Safety Lock (1)

Adhesive 

Foam Seal (1)

Frame Lock

(2)

Regular Foam

Seal (1)

Side Curtain RH (1)

Side Curtain LH (1)

Fig. 1

INSTALLATION HARDWARE

Your Room Air Conditioner is designed for easy 

installtion in a single or double-hung window. This unit

is 

NOT

designed for vertical (slider type) windows

and/or through-the-wall applications.

NOTE:

Save the shipping carton and packing materials

for future storage or transport of the unit. From carton,

remove the plastic bag containing the installation 

hardware kit necessary for the installation of your air

conditioner. Please check the contents of hardware kit

against the corresponding model check list, prior to

installation of the unit.

See Fig. 1

.

CAUTION:

Because the compressor is located on

the controls side of the unit (left side), this side will be

heavier and more awkward to manipulate. Inadequate

support on control side of the unit can result in personal

injury and damage to your unit and property. Therefore, it

is recommended that you have someone assist you during

the installation of this unit. 

F)

DO NOT install unit where leakage of 

combustible gas is suspected. Your air 

conditioner may fail to operate in air containing

oils (including machine oils), sulfide gas, near

hot springs, etc. 

Awning

Fence,
wall, or
other
obstacle

Ground

Side 

Obstruction

20”

Min

30”

Min

20”

Min

12” Min

Fig. 2

Your unit is designed to evaporate condensation
under normal conditions. However, under extreme
humidity conditions, excess condensation may
cause basepan to overflow to the outside. The unit
should be installed where condensation run-off 
cannot drip on pedestrains or neighboring properties

Summary of Contents for DAC 5209M

Page 1: ...CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit et les directives d utilisation...

Page 2: ...ION 3 IMPORTANT SAFETY INFORMATION Electrical Specifications 3 Energy Saving Tips 4 INSTALLATION 5 6 Location 5 OPERATING INSTRUCTIONS Selector Switch 7 Thermostat 7 CARE AND MAINTENANCE 8 TROUBLESHOO...

Page 3: ...ber Date of Purchase This information will be necessary if your unit requires servicing and or for general inquiries To contact a Customer Service Representative call Danby TOLL FREE 1 800 26 1 800 26...

Page 4: ...qualified electrician 5 The wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessa...

Page 5: ...only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting NOTE The power cord supplied with this air conditioner contains a...

Page 6: ...8 screws 4 Safety Lock 1 Adhesive Foam Seal 1 Frame Lock 2 Regular Foam Seal 1 Side Curtain RH 1 Side Curtain LH 1 Fig 1 INSTALLATION HARDWARE Your Room Air Conditioner is designed for easy installti...

Page 7: ...cessed portion of the window frame Pull the window down until it rests just behind the front flange of the top L shaped mounting bracket See Fig 5 Expand the shutter frames fully on each side and secu...

Page 8: ...emely hot days Once room is cooled reduce setting to LOW COOL OFF shuts down the unit completely NOTE Always allow 3 minutes before switching from one mode to another Thermostat Selector Switch THERMO...

Page 9: ...and in warm water Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results was...

Page 10: ...or outdoor louvres Turn the unit off and wait 5 minutes before attempting to restart Tighten loose parts Provide additional support to unit Clean unit thoroughly Place algaecide tablet in base pan Con...

Page 11: ...IGNES DE S CURIT IMPORTANT Sp cifications lectrique 13 Suggestions pour conomiseur de l nergie 14 INSTALLATION 15 16 Endroit 15 CONSIGNES D UTILISATION Fonction de Selection 17 Thermostat 17 SOINS ET...

Page 12: ...od le Num ro de s rie Date d achat Ces renseignements seront requis si le service est demand et ou si vous d sirez obtenir des renseignements suppl mentaires Pour consulter un Repr sentant du service...

Page 13: ...consulter un lectricien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les ren...

Page 14: ...ser le MODE DE VENTILATEUR la position HAUTE MOYENNE ou BAS Ceci fait circuler l air l int rieur de la pi ce pour fournir un certain confort de climatisation en utilisant moins d lectricit Le cordon d...

Page 15: ...le design de la fen tre peut varier it peut tre n cessaire d y faire quelques modifications pour une installation s curitaire et appropri e B Assurez vous que la fen tre et son ch ssis sont structurel...

Page 16: ...sson doit tre positionn dans le bas du cadre de la fen tre Tirez la fen tre vers le bas jusqu ce qu elle repose juste derri re le rebord frontal du canal de montage en forme de L sup rieur Voir Fig 5...

Page 17: ...AIBLE ARR T ferme le circulation compl tement REMARQUE Il faut toujours attendre 3 minutes avant de passer d un r glage un autre Thermostat Commutateur de s lection THERMOSTAT Le thermostat contr le c...

Page 18: ...FILTRE AIR 1 Utilisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneus...

Page 19: ...strue la grille ou les volets ext rieurs Arr tez le climatiseur et attendez 5 minutes avant de le remettre en marche Serrez les pi ces qui sont desserr es ou ont de jeu Fournissez un support suppl men...

Page 20: ...vice or ordering parts always provide the following information Product Type Model Number Part Number Part Description Le num ro de mod le se trouve sur la plaque d information sur le panneau arri re...

Reviews: