background image

The power cord supplied with this air conditioner contains a device that senses
damage to the power cord. To test if your power cord is working properly, you
must do the following:

Your Danby appliance is designed to be highly efficient in energy 
savings. 

Follow these recommendations for greater efficiency. 

1) 

Select a thermostat setting that suits your

comfort needs and leave at that chosen 

setting. 

2) 

The filter is very efficient in removing 

airborne particles. Keep the air filter clean.

Normally, filters should be cleaned every 2

weeks. More frequent cleaning my be 

necessary depending on indoor air quality. 

3) 

Use drapes, curtains or shades to keep

direct sunlight from penetrating and heating

room, but do not allow drapes or curtains to

obstruct the air flow around the unit.

4)

Start your air conditioner before the 

outdoor air becomes hot and uncomfortable, to

avoid an initial period of discomfort while the

unit is cooling off the room. 

5)

When outdoor temperatures are cool

enough, use HIGH or LOW FAN only. This 

circulates indoor air, providing some cooling

comfort, and utilizes less electricity than when

operating on a cooling setting. 

NOTE:

The power cord supplied with this air

conditioner contains a current leakage 

detection device designed to reduce the risk

of fire. In the event the power supply cord is

damaged, it cannot be repaired and must be

replaced with a new cord from the product

manufacturer. 

• Under no circumstances should this device

be used to turn the unit on or off. 

• The “RESET” button must always be pushed

in (engaged) for correct operation.

• The power supply cord must be replaced if it

fails to reset when the “TEST” button is

pushed in.

1) 

Connect the power supply cord to an 

electrical outlet.

2)

The power supply cord has two buttons

located on the head of the plug. One button is

marked “TEST”, and the other is marked

“RESET”. Press the “TEST” button; you will

hear a click as the “RESET” button pops out.

3)

Press the “RESET” button; you will hear a

click as the button engages.

4) 

The power supply cord is now energized

and supplying electricity to the air conditioner

(on some products this is also indicated by a

light on the plug head). 

4

IMPORTANT SAFETY INFORMATION

POWER

SUPPLY CORD

ENERGY-

SAVING TIPS

Summary of Contents for DAC 5209M

Page 1: ...CAUTION Read and follow all safety rules and operating instructions before first use of this product MISE EN GARDE Veuillez lire attentivement les consignes de s curit et les directives d utilisation...

Page 2: ...ION 3 IMPORTANT SAFETY INFORMATION Electrical Specifications 3 Energy Saving Tips 4 INSTALLATION 5 6 Location 5 OPERATING INSTRUCTIONS Selector Switch 7 Thermostat 7 CARE AND MAINTENANCE 8 TROUBLESHOO...

Page 3: ...ber Date of Purchase This information will be necessary if your unit requires servicing and or for general inquiries To contact a Customer Service Representative call Danby TOLL FREE 1 800 26 1 800 26...

Page 4: ...qualified electrician 5 The wall outlet must match the 3 prong plug on the service cord supplied with the unit DO NOT use plug adapters See Table 2 for receptacle and fuse information If it is necessa...

Page 5: ...only This circulates indoor air providing some cooling comfort and utilizes less electricity than when operating on a cooling setting NOTE The power cord supplied with this air conditioner contains a...

Page 6: ...8 screws 4 Safety Lock 1 Adhesive Foam Seal 1 Frame Lock 2 Regular Foam Seal 1 Side Curtain RH 1 Side Curtain LH 1 Fig 1 INSTALLATION HARDWARE Your Room Air Conditioner is designed for easy installti...

Page 7: ...cessed portion of the window frame Pull the window down until it rests just behind the front flange of the top L shaped mounting bracket See Fig 5 Expand the shutter frames fully on each side and secu...

Page 8: ...emely hot days Once room is cooled reduce setting to LOW COOL OFF shuts down the unit completely NOTE Always allow 3 minutes before switching from one mode to another Thermostat Selector Switch THERMO...

Page 9: ...and in warm water Dry thoroughly before re installing CLEANING AIR FILTER 1 Use a vacuum cleaner with soft brush attachment 2 Wash the filter in lukewarm water below 40 C 104 F To get best results was...

Page 10: ...or outdoor louvres Turn the unit off and wait 5 minutes before attempting to restart Tighten loose parts Provide additional support to unit Clean unit thoroughly Place algaecide tablet in base pan Con...

Page 11: ...IGNES DE S CURIT IMPORTANT Sp cifications lectrique 13 Suggestions pour conomiseur de l nergie 14 INSTALLATION 15 16 Endroit 15 CONSIGNES D UTILISATION Fonction de Selection 17 Thermostat 17 SOINS ET...

Page 12: ...od le Num ro de s rie Date d achat Ces renseignements seront requis si le service est demand et ou si vous d sirez obtenir des renseignements suppl mentaires Pour consulter un Repr sentant du service...

Page 13: ...consulter un lectricien qualifi 5 La prise murale doit correspondre la fiche 3 broches sur le cordon de service fourni avec l appareil N utilisez PAS de fiches d adaptation Voir Tableau 2 pour les ren...

Page 14: ...ser le MODE DE VENTILATEUR la position HAUTE MOYENNE ou BAS Ceci fait circuler l air l int rieur de la pi ce pour fournir un certain confort de climatisation en utilisant moins d lectricit Le cordon d...

Page 15: ...le design de la fen tre peut varier it peut tre n cessaire d y faire quelques modifications pour une installation s curitaire et appropri e B Assurez vous que la fen tre et son ch ssis sont structurel...

Page 16: ...sson doit tre positionn dans le bas du cadre de la fen tre Tirez la fen tre vers le bas jusqu ce qu elle repose juste derri re le rebord frontal du canal de montage en forme de L sup rieur Voir Fig 5...

Page 17: ...AIBLE ARR T ferme le circulation compl tement REMARQUE Il faut toujours attendre 3 minutes avant de passer d un r glage un autre Thermostat Commutateur de s lection THERMOSTAT Le thermostat contr le c...

Page 18: ...FILTRE AIR 1 Utilisez un aspirateur de poussi re muni d une brosse douce 2 Lavez le filtre dans de l eau ti de de moins de 40 C 104 F Pour obtenir de meilleurs r sultants lavez avec une eau savonneus...

Page 19: ...strue la grille ou les volets ext rieurs Arr tez le climatiseur et attendez 5 minutes avant de le remettre en marche Serrez les pi ces qui sont desserr es ou ont de jeu Fournissez un support suppl men...

Page 20: ...vice or ordering parts always provide the following information Product Type Model Number Part Number Part Description Le num ro de mod le se trouve sur la plaque d information sur le panneau arri re...

Reviews: