Axis Port DC Outputs
Number of outputs
2 outputs per axis
Configuration
Each set of axis outputs can be configured as sourcing or
sinking.
Maximum current
100 mA per output
Voltage range
24 VDC nominal, 5 to 30 VDC range
Scan loss response
Outputs turn off
Aux Port +5 Vdc Output
+5 VDC
150 mA maximum current available. Connections to this
point should be over short distances and away from electric
noise signals.
SERCOS Motion Board
SERCOS Interface
Interfaces with one ring (MMC-S8) or two rings (MMC-S16)
with from one to eight Sercos drives per ring
SERCOS port
SMA female connectors for interfacing to 1000 µ meter plas-
tic fiber optic cable with SMA male connectors.
Fiber optic receiver specifications:
Peak input power (optical level low) -31.2dBm max
Peak input power (optical level high) -20.0 dBm min,
0.0dBm max
Fiber optic transmitter specifications:
Peak output power (optical level high) is -10.5 dBm min,
-5.5 dBm max
Update loader port
RS232 interface
SERCOS Cable
Type
Plastic with step index profile (POF)
Core diameter
Fiber diameter
980 µm ±60 µm
1000 µm ±60 µm
Operating temperature
0° C to 55° C (32° F to 131° F)
Minimum bend radius
One time: 30 mm
Continuous: 80 mm
Tensile strength
One time: 250 N
Continuous: 100 N
Connectors
SMA style male
Summary of Contents for Standalone MMC
Page 4: ......
Page 8: ...8 Standalone MMC Hardware Manual Table of Contents version 15 1 Danaher Motion ...
Page 94: ...94 Standalone MMC Hardware Manual Standalone MMC Control version 15 1 Danaher Motion ...
Page 169: ...Standalone MMC Hardware Manual 169 Danaher Motion version 15 1 CE and EMC Guidelines ...
Page 170: ...170 Standalone MMC Hardware Manual CE and EMC Guidelines version 15 1 Danaher Motion ...
Page 171: ...Standalone MMC Hardware Manual 171 Danaher Motion version 15 1 CE and EMC Guidelines ...
Page 172: ...172 Standalone MMC Hardware Manual CE and EMC Guidelines version 15 1 Danaher Motion ...