SAFETY & WARNINGS
:
Only qualified personnel are permitted to transport, assembly, commission,
and maintenance this equipment. Properly qualified personnel are persons
who are familiar with the transport, assembly, installation, commissioning
and operation of motors, and who have the appropriate qualifications for
their jobs. The qualified personnel must know and observe the following
standards and regulations:
IEC 364 resp. CENELEC HD 384 or DIN VDE 0100
IEC report 664 or DIN VDE 0110
National regulations for safety and accident prevention or VBG 4
CAUTION
Read all available documentation before assembly and
commissioning. Incorrect handling of products in this manual can
result in injury and damage to persons and machinery. Strictly adhere
to the technical information on the installation requirements.
CAUTION
It is vital to ensure that all system components are connected to earth
ground. Electrical safety is impossible without a low-resistance earth
connection
.
WARNING
The SERVOSTAR product contains electro-statically sensitive
components that can be damaged by incorrect handling. Discharge
yourself before touching the product. Avoid contact with high
insulating materials (artificial fabrics, plastic film, etc.). Place the
product on a conductive surface.
WARNING
During operation keep all covers and cabinet doors shut. Otherwise,
there are deadly hazards that could possibility cause severe damage
to health or the product.
WARNING
In operation, depending on the degree of enclosure protection, the
product can have bare components that are live or have hot surfaces.
Control and power cables can carry a high voltage even when the
motor is not rotating.
WARNING
Never pull out or plug in the product while the system is live. There is
a danger of electric arcing and danger to persons and contacts.
WARNING
After powering down the product, wait at least ten minutes before
touching live sections of the equipment or undoing connections (e.g.,
contacts, screwed connections). Capacitors can store dangerous
voltages for long periods of time after power has been switched off.
To be safe, measure the contact points with a meter before touching.
DIRECTIVES & STANDARDS
The SERVO
STAR
S and SERVO
STAR
CD product series have been
successfully tested and evaluated to meet UL/cUL 508C for both U.S. and
Canadian markets. This standard describes the fulfillment by design of
minimum requirements for electrically operated power conversion
equipment, such as frequency converters and servo amplifiers, which is
intended to eliminate the risk of fire, electric shock, or injury to persons,
being caused by such equipment.