Danaher Motion Kollmorgen
Installation
2. 2
I
RONCORE
S
INGLE
M
AGNET
P
LATE
I
NSTALLATION
WARNING
For safety reasons, construct jacking plates to prepare the magnet
way and coil for installation into the stage.
1. Lightly stone and thoroughly clean the mounting surfaces on the stage for
both coil and magnet way
2. Install the magnet plate onto the base of the stage.
3. Attach the jacking plate(s) to the coil assembly using M5 screws (shown in
the
Figure 1 Multiple Magnet Diagram
Extend jacking screws (4 per
plate) completely through the jacking plate(s) (see the
Figure 2 Single
Magnet Diagram
).
NOTE
Multiple jacking plates are required for sizes 22, 33,
44, 55, and 66 coils.
4. For IC, place 0.031 inch (0.8 mm) thick, soft non-magnetic shim material
(slightly larger than the coil surface) on the magnet plate. For ICD, use a
0.028 inch (0.7 mm) shim. Carefully place the coil assembly on top of the
shim so that the coil assembly is supported over the magnets by the
jacking screws resting on the magnet plate surface.
5. Slowly lower the coil assembly onto the magnets by loosening the jacking
screws sequentially to keep the coil assembly parallel to the magnet plate.
Remove the jacking plate(s) when the coil is fully lowered.
6. Move the slide over the coil assembly. Use brass or stainless steel shims to
establish the total shim thickness required between the coil mounting
surface and the mating slide (bottom) surface.
7. Mount the coil assembly (including the selected shim) into the slide using
M5 screws. Tighten screws sequentially to properly seat the coil
assembly.
8. Remove the plastic shim from the magnet plate
M-LN-016-0702 Rev D
05/07
7